A fix is available
APAR status
Closed as program error.
Error description
After IPL, Netview experienced abend0c4 in INGCHW0A. Message ING815I BCPII CONNECT SUCCESS was received a minute before the abend. The code is not acting properly after a successful INTERNAL connect (ING815I) in case the very 1st query (console name) fails. This can be the case if the SE/HMC has not yet completed the startup of its HWMCA console application. This error should terminate with ING817I instead of continuing the INITCOM to discover other SE data.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All System Automation for z/OS V3.5 * * customers using SA-BCPii based functions or * * service offerings to monitor and control IBM * * z mainframes, supported with SA z/OS. * **************************************************************** * PROBLEM DESCRIPTION: In situations with sequences of * * unintended or intended Support Element * * reboots it can happen, that the overall * * wait-time of a currently active * * SA-BCPii session initialization runs * * out, while the SE console application * * still performs work for the SA-BCPii * * session requestor, especially if the * * Support Element itself is not yet fully * * initialized. As a result of the overall * * timeout, the SA-BCPii session is * * unconditionally terminated to allow new * * requests later on. The SE console * * request data that is now returned in * * such as situation no longer finds valid * * session storage, which may cause an * * ABEND0C4 in INGCHW00. * **************************************************************** * RECOMMENDATION: * **************************************************************** SE reboot sequences may cause ABEND0C4 in INGCHW00 if the SA-BCPii session initialization requests are not delayed or deferred.
Problem conclusion
Clist INGRX810/INGHWCMD has been changed. The default timeout value added to the INITCOM/SUSPEND command has been increased from 5 to 10 Minutes. The overall default timeout value is now 13 minutes for each of them. If the INITCOM/RESUME commands have been specified with a user timeout, now 10 instead of 5 minutes are added. Note, that these changes apply to SA-BCPii (protocol INTERNAL) connections only.
Temporary fix
Comments
APAR Information
APAR number
OA51011
Reported component name
SYSTEM AUTO Z/O
Reported component ID
5698SA300
Reported release
350
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-08-02
Closed date
2016-09-23
Last modified date
2016-10-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA82869
Modules/Macros
INGRX810
Fix information
Fixed component name
SYSTEM AUTO Z/O
Fixed component ID
5698SA300
Applicable component levels
R350 PSY UA82869
UP16/09/29 P F609
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSWRCJ","label":"IBM Tivoli System Automation for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"350","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
04 October 2016