IBM Support

OA49609: NEW IBM MAINFRAME Z13S D/T2965 AND Z13 D/T2964 NEW MCL TOLERATION SUPPORT

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • With this fix, the new IBM z system z13s, device type 2965 is
    recognized and shown in the SA z/OS hardware query
    responses or runtime panel displays. You can define processor
    entries to address D/T2965 in your SA policy.
    
    The released microcode levels for D/T2965 and D/T2964 allow the
    SA z/OS ProcOps and the SA-BCPii hardware interfaces to
    recognize KVM on z System instances running in a logical
    partition. The released microcode levels for D/T2965 and D/T2964
    allow the SA z/OS ProcOps and the SA-BCPii hardware interfaces
    to recognize hardware or software appliance infrastructure
    instances running in a logical partition.
    

Local fix

  • n/a
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All System Automation for z/OS customers of  *
    *                 the releases V3.4 and V3.5 using the         *
    *                 Processor Operations function or the BCP     *
    *                 Internal Interface (BCPii) function of the   *
    *                 product to monitor and control their         *
    *                 processor target hardware / target systems.  *
    ****************************************************************
    * PROBLEM DESCRIPTION: This fix provides code changes to       *
    *                      tolerate the new IBM zEnterprise z13    *
    *                      GA2 Mainframe-System as a target for    *
    *                      the SA z/OS HW interfaces.              *
    *                                                              *
    *                      This fix also provides documentation    *
    *                      changes about new IML Mode DPM (IBM     *
    *                      Dynamic Partition Manager) with         *
    *                      regard to using the Hardware            *
    *                      Interface of System Automation for zOS. *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    The following changes are introduced with this toleration
    support:
    
    1. Support recognition and display of new Operating system type
       "KVMIBM".
    
    2. Support recognition and display of new CPC Image Mode "zACI"
       (z Appliance Container Infrastructure)
    
    3. Correctly display Absolute Capping value for SA hardware
       command 'ICNTL' (Image Control).
    

Problem conclusion

Temporary fix

Comments

  • The following change is introduced for SA documentation
    "Planning and Installation":
    
    +==============================================================+
    |                                                              |
    | Chapter 1:  Prerequisits and Supported Equipment             |
    | Section:    Hardware Requirments                             |
    | Paragraph:  Functional Prerequisites                         |
    |                                                              |
    | Append the following new text block to the paragraph         |
    |==============================================================|
    |                                                              |
    | With SE/HMC Workplace Version 2.13.1, a new IML mode for     |
    | CPCs, IBM Dynamic Partition Manager (DPM) is available. The  |
    | following additional prerequisits apply:                     |
    |                                                              |
    | o  SE: Workplace Version 2.13.1                              |
    |                                                              |
    |    The attached CPC must run in PR/SM mode, the DPM mode is  |
    |    not supported by the SA z/OS processor hardware           |
    |    interfaces (ProcOps, SA-BCPii).                           |
    |                                                              |
    | o  HMC Workplace Version 2.13.1                              |
    |                                                              |
    |    At least one of the defined CPCs in the Defined CPC Group |
    |    must run in PR/SM mode, otherwise this HMC cannot be used |
    |    to target processors or systems using a ProcOps connection|
    |    to this HMC.                                              |
    |                                                              |
    |    At least one of the defined CPCs in the Defined CPC Group |
    |    must run in PR/SM mode, otherwise the SA-BCPii requests   |
    |    routing function is not operational.                      |
    |                                                              |
    +--------------------------------------------------------------+
    

APAR Information

  • APAR number

    OA49609

  • Reported component name

    SYSTEM AUTO Z/O

  • Reported component ID

    5698SA300

  • Reported release

    350

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-12-17

  • Closed date

    2016-03-03

  • Last modified date

    2016-04-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UA80885 UA80886

Modules/Macros

  • INGCHW00 INGHW0VN INGRX810
    

Publications Referenced
SC34264500SC34271600   

Fix information

  • Fixed component name

    SYSTEM AUTO Z/O

  • Fixed component ID

    5698SA300

Applicable component levels

  • R340 PSY UA80885

       UP16/03/05 P F603

  • R350 PSY UA80886

       UP16/03/05 P F603

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSWRCJ","label":"IBM Tivoli System Automation for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"350","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
05 April 2016