IBM Support

OA44320: MESSAGES DWO970I AND DWO050E ISSUED WHEN RUNNING CLIST PFKDEF WITH APAR OA43146 PTF UA71612 APPLIED. 14/01/23 PTF PECHANGE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Messages DWO970I and DWO050E are issued when running clist
    PFKDEF with APAR OA43146 PTF UA71612 applied.
    
    
    DWO970I PFKDEF : QSAM-READ FAILED WITH RETURN CODE +0000001012.
    DWO050E FOR PROBLEM DEBUG:  COMPONENT: QSAM  MODULE: DSIQSGET
    RC: 1012
    

Local fix

  • Back off APAR OA43146 PTF UA71612
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Tivoli NetView for z/OS users who have   *
    *                 PTF UA71612 applied.                         *
    ****************************************************************
    * PROBLEM DESCRIPTION: Several possible problems can occur     *
    *                      (one of which follows) after PTF        *
    *                      UA71612 is applied.                     *
    *                      When attempting to load an empty PF key *
    *                      definition using the PFKDEF command,    *
    *                      the following messages are issued:      *
    *                      DWO050E FOR PROBLEM DEBUG:  COMPONENT:  *
    *                        QSAM  MODULE: DSIQSGET  RC: 1012      *
    *                        GET for SYS00255 , but DCB not open   *
    *                      DWO970I PFKDEF : QSAM-READ FAILED WITH  *
    *                        RETURN CODE +0000001012               *
    *                      And the PF key definitions are not set. *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    The NetView recovery and retry logic for some modules is not
    capturing the return code from the NetView DSIESTAE macro when
    an error (abend) is handled by the DSIESTAE macro. This leaves
    the return code set to zero causing the subsequent code to
    follow a path intended only for a successful completion of the
    preceding code. This path may eventually discover the error and
    issue messages (e.g. msgDWO050E and msgDWO970I) indicating a
    problem or possibly result in various abends. For example if a
    PIPE QSAM stage QSAM OPEN fails, the OPEN return code remains
    zero. Then the QSAM stage proceeds to do a QSAM GET which fails
    because the file was not opened. This results in the reported
    DWO050E message. If the QSAM PIPE stage is the one used by the
    PFKDEF command and it references an empty PFK definition member,
    the reported DWO970I message may also be issued and the PF keys
    may not get set.
    Other possible NetView components affected include (but are not
    limited to):
    - the following PIPE stages: MEMLIST, PPI, TSO, and UNIX.
    - REXX program termination where the EXECIO command was used
      without a FINIS argument and EXECIO command usage in general
      where errors are encountered.
    - the REXX STORAGE function when attempting to reference
      unallocated storage.
    These problems are the result of the erroneous fix for APAR
    OA43146/PTF UA71612.
    

Problem conclusion

  • Code in various parts are being changed to correctly set the
    return code from the DSIESTAE macro.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA44320

  • Reported component name

    NETVIEW FOR Z/O

  • Reported component ID

    5697ENV00

  • Reported release

    54B

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-01-23

  • Closed date

    2014-02-21

  • Last modified date

    2014-04-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UA72509

Modules/Macros

  •    CNMCSSIR DSICCF   DSIC2FLT DSIDCBMT DSIDCLS
    DSIDIAGX DSIDOPS  DSIDOS   DSIDRS   DSIDUBIT DSIDUMPF DSIFLT2C
    DSIFMN   DSIGV2VR DSILSMEM DSIMECBP DSIMREST DSIMSX   DSIMTM
    DSIPIMML DSIPIPPI DSIPIQSM DSIPITSO DSIPIUNX DSIQOM   DSIQSEND
    DSIQSGET DSIQSPUT DSIRXDII DSIRXFSI DSIRXWRX DSISBSYS DSISCHEX
    DSISHWVR DSISTAEX DSITEPSM DSITIB   DSITIMMT DSITSONM DSITSTAT
    DSITUREC DSIWTOMT
    

Fix information

  • Fixed component name

    NETVIEW FOR Z/O

  • Fixed component ID

    5697ENV00

Applicable component levels

  • R54B PSY UA72509

       UP14/03/18 P F403

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJDU","label":"IBM Z NetView"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"54B","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
02 April 2014