Error description
The customer has added a CANZLOG CUE command as part of the PHASE 2 shutdown for SA and GDSP. The command fails with message DWO373E and then BNH355E. Earlier the same command was issued as part of SHUTFINAL for JES2. The error messages are due to the CANZLOG CUE command being issued within a PIPE.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All SA z/OS V3R3 and V3R4 customers using * * GDPS controlled system shutdown method. * **************************************************************** * PROBLEM DESCRIPTION: MsgDWO373E "ERROR: IMPROPER TRAPPING OF * * MESSAGES WITHIN A PIPELINE" can be * * issued when shutting down systems under * * GDPS control. * **************************************************************** * RECOMMENDATION: * **************************************************************** MsgDWO373E should not be issued when shutting down systems under GDPS control.
Problem conclusion
Rexx routine INGRVRU4 has been changed to avoid MsgDWO373E.
Temporary fix
Comments
APAR Information
APAR number
OA43535
Reported component name
SYSTEM AUTO Z/O
Reported component ID
5698SA300
Reported release
340
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2013-10-02
Closed date
2013-10-17
Last modified date
2013-11-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA71114 UA71115
Modules/Macros
INGRVRU4
Fix information
Fixed component name
SYSTEM AUTO Z/O
Fixed component ID
5698SA300
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSWRCJ","label":"IBM Tivoli System Automation for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"340","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
04 November 2013