A fix is available
APAR status
Closed as program error.
Error description
The Omegamon Base SRB driver abends with an 0c1 with UA67744 or UA67745 applied.
Local fix
PTF
Problem summary
**************************************************************** * USERS AFFECTED: All OMEGAMON BASE users. * **************************************************************** * PROBLEM DESCRIPTION: PEEK and XMLS fail with * * >> OB8112: Data Collection Initiated << * * >>> Warning <<< SRB Routine Terminated * * Abnormally - RC = S0C1 * **************************************************************** * RECOMMENDATION: Apply this PTF. * **************************************************************** OMEGAMON Commands that schedule SRBs fail due to a bad branch to a location within the SRB.
Problem conclusion
Correct the SRB code.
Temporary fix
Comments
APAR Information
APAR number
OA41694
Reported component name
OMNIMON BASE
Reported component ID
5608A41OB
Reported release
620
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-03-15
Closed date
2013-03-26
Last modified date
2013-05-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA68461 UA68462
Modules/Macros
KOBSRBDM
Fix information
Fixed component name
OMNIMON BASE
Fixed component ID
5608A41OB
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSC6MLD","label":"IBM Tivoli OMEGAMON OMNIMON Base"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
03 May 2013