A fix is available
APAR status
Closed as program error.
Error description
An incorrect update to the SDFROOT value on a Netview in a system which runs two NetViews was made. This resulted in both NetViews having the same SDFROOT value, and the gateway autotask failing on the SDF focal point. This resulted in a message: AOF776I CONNECTION FROM DOMAIN xxxxx xxxx REJECTED AT DOMAIN xxxx SDFROOT NAME IS THE SAME AS DOMAIN xxxxx. SA immediately restarted the gateway autotask which failed and restarted in a loop.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All SA z/OS V3R2, V3R3 and V3R4 customers. * **************************************************************** * PROBLEM DESCRIPTION: When msgAOF776I is issued indicating a * * rejected connection, the connecting * * task is logged off. This in turn can * * cause AOFR1ILL to be issued from the AT * * to log this task back on and therefore * * creating a loop. One of the causes of * * this can be a wrongly defined SDF root. * **************************************************************** * RECOMMENDATION: * **************************************************************** A loop caused by a wrongly defined SDF root should not cause a logon/logoff loop for the task in question, normally the gateway task for the remote system.
Problem conclusion
Rexx routines INGRVXMT and AOFR1ILL have been changed to avoid a logon/logoff loop when a SDF root has been defined incorrectly.
Temporary fix
Comments
APAR Information
APAR number
OA39554
Reported component name
SYSTEM AUTO Z/O
Reported component ID
5698SA300
Reported release
330
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2012-05-10
Closed date
2012-05-22
Last modified date
2012-06-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA65417 UA65418 UA65419
Modules/Macros
AOFR1ILL INGRVXMT
Fix information
Fixed component name
SYSTEM AUTO Z/O
Fixed component ID
5698SA300
Applicable component levels
R320 PSY UA65417
UP12/05/26 P F205
R330 PSY UA65418
UP12/05/26 P F205
R340 PSY UA65419
UP12/05/26 P F205
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSWRCJ","label":"IBM Tivoli System Automation for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"330","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
03 June 2012