IBM Support

OA38919: TEMS CRASH IN SUBNODE REGISTRATION

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • TEMS crash with the following call stack if KPX trace is enabled
    
    kbb!RAS1_Format+0x36
    kbb!RAS1_Printf+0x1f
    KRANDREG!CTIRA_FindAttrStart+0x1cf
    KRANDREG!IRA_NCS_Subnode_Request+0x310
    KRANDREG!IRA_NCS_Subnode_Request_ssr+0x869
    
    Approver Initials: LK
    

Local fix

  • Turn off KPX trace
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All TEMS users.                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: THE MONITORING SERVER CRASHES AFTER     *
    *                      TURNING ON KPX TRACE                    *
    ****************************************************************
    * RECOMMENDATION: Apply the PTF.                               *
    ****************************************************************
    Incorrectly calculated print format precision specifier
    causes the monitoring server to crash if KPX trace is
    enabled.
    

Problem conclusion

  • The monitoring server subnode registration module now
    correctly calculates print formatting precision.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA38919

  • Reported component name

    MGMT SERVER DS

  • Reported component ID

    5608A2800

  • Reported release

    623

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-02-27

  • Closed date

    2012-03-05

  • Last modified date

    2012-04-03

  • APAR is sysrouted FROM one or more of the following:

    IV06261

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • KDSMAIN
    

Fix information

  • Fixed component name

    MGMT SERVER DS

  • Fixed component ID

    5608A2800

Applicable component levels

  • R623 PSY UA64468

       UP12/03/09 P F203

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSRJ5K","label":"Tivoli Management Server for Distributed Systems on z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"623","Edition":"","Line of Business":{"code":"LOB17","label":"Mainframe TPS"}}]

Document Information

Modified date:
03 April 2012