A fix is available
APAR status
Closed as program error.
Error description
Customer is experiencing a storage growth in NetView in SP2 key8 and causes an out of storage condition. The problem appears to be due to INITCOM failures for a CPC that is not yet operational but has been defined.
Local fix
stop the monitoring (INGRX830) of the Non-GDPS controlled BCPii connections by purging the SYSxxxx timers that schedules INGRX830. This will stop the suspected failing INITCOM calls and stop the storage growth.
Problem summary
**************************************************************** * USERS AFFECTED: All System Automation for z/OS users of the * * releases 3.2 or 3.3, using the BCP Internal * * Interface, Processor Operations, or both to * * monitor and control their System z mainframe * * processors. * **************************************************************** * PROBLEM DESCRIPTION: Over the time, the Netview private * * allocated storage use may increase, in * * case BCPii or ProcOps session starts * * fail. In some cases, the session * * storage, allocated by INGCHW00 seems * * not to be released. * **************************************************************** * RECOMMENDATION: * **************************************************************** Netview private allocated storage usage may be exceeded if session INITCOM fails.
Problem conclusion
Module INGCHW00 was changed. The storage anchor address of the allocated storage, if available, is now copied into a local pgm variable, independent from the INITCOM result. This variable is then referenced at session termination time to free the session allocated memory. Sub-module INGHW0VN was changed to indicate the current module version.
Temporary fix
Comments
APAR Information
APAR number
OA37069
Reported component name
SYSTEM AUTO Z/O
Reported component ID
5698SA300
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2011-07-15
Closed date
2011-08-23
Last modified date
2011-09-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA61901 UA61902
Modules/Macros
INGCHW00 INGHW0VN
Fix information
Fixed component name
SYSTEM AUTO Z/O
Fixed component ID
5698SA300
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSWRCJ","label":"IBM Tivoli System Automation for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"320","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: