APAR status
Closed as program error.
Error description
Data sets migrated with CONSOLIDATE_ALL option can have an invalid USED TRACKS value and the last volume indicator may be incorrect causing an abend S637-BC when reading.
Local fix
Do not use CONSOLIDATE_ALL option.
Problem summary
**************************************************************** * USERS AFFECTED: zDMF users setting the CONSOLIDATE_ALL * * option to YES. * **************************************************************** * PROBLEM DESCRIPTION: Abend S637-BC and incorrect used track * * values on sequential data sets. * **************************************************************** * RECOMMENDATION: Apply PTF and WARM start the servers. * **************************************************************** An abend S637-BC can occur while reading a sequential data set and the used tracks value can be incorrect for data sets migrated with the CONSOLIDATE_ALL option.
Problem conclusion
The last volume indicator and last track/record used values are now reassessed at divert.
Temporary fix
Comments
APAR Information
APAR number
OA36287
Reported component name
SOFTEK ZDMF
Reported component ID
694932D00
Reported release
325
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-04-27
Closed date
2011-06-13
Last modified date
2014-06-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA60845
Modules/Macros
GZDACT1 GZDRENV GZDRMAN
Fix information
Fixed component name
SOFTEK ZDMF
Fixed component ID
694932D00
Applicable component levels
R325 PSY UA60845
UP11/08/12 P F405