A fix is available
APAR status
Closed as new function.
Error description
Small enhancements . INGTHRES does not fully support thresholds for minor resources. . Incorrect return code assignment in EVIEX002 should be removed (lrc = rc). . Potential NOVALUE CONDITION IN INGRX740 (AOF760E NOVALUE CONDITION TRAPPED IN INGRX740 LINE 38 (CODE N/A) DESCRIPTION WAITTIME).
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All SA z/OS V3R1 customers. * **************************************************************** * PROBLEM DESCRIPTION: There are 31 enhancements: * * * * 1. Panel AOFKAASR only reflects up to * * 16 characters of the resource name * * which can contain up to 32 * * characters. * * 2. MsgAOF760E can be received for * * EVIEX002 when rc is not initialized. * * 3. EVJESHUT does not appear in the * * replaced commands table in the * * migration guide from SA23. * * 4. MsgAOF760E can be received for * * INGRX740. * * 5. AOF_INIT_ROUTCDE does not set all * * 16 route codes. * * 6. When using wildcards to list * * resources using INGLIST inconsistent * * results may be returned. * * 7. Panel EVJKYST0 does not show the * * correct data. * * 8. MsgAOF110I does not mention * * REFRESHED. * * 9. AM workitem footprint does not * * always give a reason. * * 10. Missing description for preference * * value 400 on panel AOFHARS2 (Select * * Resources Help). * * 11. Remove msg class 80 from INGNTFY * * call. * * 12. INGMOVE invokation of exit * * AOFEXC13. * * 13. Pass non-zero RC back to caller of * * INGGROUP. * * 14. Data may be mixed up if panel * * AOFGOSOA is left with CANCEL. * * 15. Missing EXEC statement added to * * INGEBBLD. * * 16. Add PRECHECK=NO for E2E requests. * * 17. Avoid msgIEE731I to be returned as * * data. * * 18. Run INGRVX91 on local system only. * * 19. Issue message if incomplete * * MESSAGES/USER DATA block in flat file. * * 20. Stores control variable in shared * * pool. * * 21. Modifies application type change. * * 22. Correct APG target value handling. * * 23. Modify entry selection for PDB * * import. * * 24. Describe modified selections and * * add 'S *' and 'R *' selections. * * 25. Detect SYS-PRO and SYS-Sysplex * * link conflicts. * * 26. Add msgAOFD252U Selection mismatch. * * 27. Fix INGE2E RESET function. * * 28. Allow 0 as DB2 active log alert * * threshold value (DSNJ111E). * * 29. Panels INGLX252 and INGLX262 say * * SUMSUMP and not SUMDUMP. * * 30. Correct PLEXNAME behavior. * * 31. Correct output lines. * **************************************************************** * RECOMMENDATION: * **************************************************************** Panel AOFKAASR should reflect the whole resource name. MsgAOF760E should never be issued. The SA23 migration guide should list EVJESHUT as a replaced command. AOF_INIT_ROUTCDE should have all 16 bits set at initialization. Inconsistent results should not be returned by INGLIST when using wildcards. Panel EVJKYST0 should show the data correctly. MsgAOF110I should explain the REFRESHED origin. The AM workitem should show a reason in the footprint why it was created. Panel AOFHARS2 should contain a description for preference value 400. Remove msg class 80 from INGNTFY call. INGMOVE invokation of exit AOFEXC13. Pass non-zero RC back to caller of INGGROUP. Data may be mixed up if panel AOFGOSOA is left with CANCEL. Missing EXEC statement added to INGEBBLD. Add PRECHECK=NO for E2E requests. Avoid msgIEE731I to be returned as data. Run INGRVX91 on local system only. Issue message if incomplete MESSAGES/USER DATA block in flat file. Stores control variable in shared pool. Modifies application type change. Correct APG target value handling. Modify entry selection for PDB import. Describe modified selections and add 'S *' and 'R *' selections. Detect SYS-PRO and SYS-Sysplex link conflicts. Add msgAOFD252U Selection mismatch. Fix INGE2E RESET function Allow 0 as DB2 active log alert threshold value (DSNJ111E). Panels INGLX252 and INGLX262 should say SUMDUMP and not SUMSUMP. INGRX200 should correct PLEXNAME behavior. INGRX251 should correct output lines.
Problem conclusion
Temporary fix
n/a
Comments
Rexx routines INGRYTH0, AOFRVDA4, AOFRATHU and AOFRVTHU have been changed to enable the update of a 32 character resource name. Panel AOFKAASR has been changed to enable the display of a 32 character resource name. Rexx routines EVIEX002 and INGRX740 have been changed to avoid msgAOF760E. Rexx macro AOFC0146 has been changed to ensure consistent results are returned by INGLIST. Rexx routines EVJEAC02, EVJEOBSV, INGRVGRA and INGRVST0 have been shipped to carry changes to AOFC0146. Sample AOFSTYLE has been changed to set all 16 bits for AOF_INIT_ROUTCDE. Rexx routine EVJRYST0 has been changed to correctly display the data on panel EVJKYST0 (INGOPC * REQ=LIST TYPE=WS). Panel AOF11 has been changed to explain the REFRESHED origin. Rexx macro AOFC0189 has been changed to pass a reason to the manager. Rexx routines AOFRARC, AOFRSMOO, AOFRVDA8, EVEEI006, EVEETUOW EVEET002, EVEET021, EVERX002, EVERX003 and EVERYSTS have been shipped to carry the change to AOFC0189. Panel AOFHARS2 has been changed to include a description of preference value 400. Rexx routine INGRTIN has been changed to remove msg class 80 from INGNTFY call. Rexx routines INGRYMV0 and INGRYMV1 have been changed to invoke exit AOFEXC13. Rexx routine INGRYGRA has been changed to pass non-zero RC back to caller. Rexx macros AOFC0182 and MAPPER has been changed for new common include for calling exit #13. Rexx routine AOFFVTDA has been changed as data may be mixed up if panel AOFGOSOA is left with CANCEL. Sample INGEBBLD has been changed for missing EXEC statement to be added. Rexx macro AOFC0207 has been changed to add PRECHECK=NO for E2E requests. Rexx routine INGRXTX0 has been shipped to carry the change to AOFC0207. Rexx routine INGRXTXP has been changed to Fix INGE2E RESET function. Rexx routine INGRVX27 has been changed to avoid msg IEE731 to be returned as data. Rexx routine INGRX809 has been changed to run INGRVX91 on local system only. ISPF table AOFT0REN has been changed to correct relationship if MTRNAME changed. Rexx routine AOFFPFLA has been changed to issue message if incomplete MESSAGES/USER DATA block in flat file. Rexx routine AOFFPFLT has been changed to store control variable in shared pool. Rexx routine AOFFFAPL has been changed to modify application type change. Rexx routine AOFFPIM2 has been changed to correct APG target value handling. Messages AOFD24 has been changed to correct APG target value handling. Panel AOFGIMPS has been changed to modify entry selection for import. Panel AOFHIMPS has been changed to describe modified selections. Rexx routine AOFFPIM3 has been changed to add 'S *' and 'R *' selections. Rexx routine AOFFPIM4 has been changed to perform scrolling before actions. Rexx macro AOFC1034 has been changed to correct CheckDuplicateInList table and detect SYS-PRO and SYS-Sysplex link conflicts. Messages AOFD25 has been changed to add AOFD252U 'Selection mismatch'. Panels AOFPDXL and AOFHDXL have been changed to allow 0 as DB2 active log alert threshold value (DSNJ111E). Panels INGLX252 and INGLX262 have been changed to say SUMDUMP instead of SUMSUMP. Rexx routine INGRX200 has been changed to correct PLEXNAME behavior. Rexx routine INGRX251 has been changed to correct output lines.
APAR Information
APAR number
OA21564
Reported component name
SYSTEM AUTO Z/O
Reported component ID
5698SA300
Reported release
310
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2007-06-27
Closed date
2007-09-26
Last modified date
2007-11-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA37007 UA37008
Modules/Macros
AOFD24 AOFD25 AOFFFAPL AOFFPFLA AOFFPFLT AOFFPIM2 AOFFPIM3 AOFFPIM4 AOFFVTDA AOFGIMPS AOFHARS2 AOFHDXL AOFHIMPS AOFKAASR AOFPDXL AOFRARC AOFRATHU AOFRSMOO AOFRVDA4 AOFRVDA8 AOFRVTHU AOFSTYLE AOFT0REN AOF11 EVEEI006 EVEETUOW EVEET002 EVEET021 EVERX002 EVERX003 EVERYSTS EVIEX002 EVJEAC02 EVJEOBSV EVJRYST0 INGEBBLD INGLX252 INGLX262 INGRTIN INGRVGRA INGRVST0 INGRVVA0 INGRVX27 INGRXTXP INGRXTX0 INGRX200 INGRX251 INGRX740 INGRX809 INGRYGRA INGRYMV0 INGRYMV1 INGRYTH0
| SC33826103 | SC33826403 | SC33826203 |
Fix information
Fixed component name
SYSTEM AUTO Z/O
Fixed component ID
5698SA300
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSWRCJ","label":"IBM Tivoli System Automation for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: