Error description
Rational Developer for System z - RDz - v8.5.1: When editing a copybook file if COPY is used in a field name within (as ''A'-COPY'), LPEX editor wrongly marks it with this annotation ''TextNameLiteral' expected after this token.' *************************************************************** Local fix: None
Local fix
Problem summary
When the real time syntax parser for COBOL encounters the text "COPY", it treats it at the start of a copy statement, and reports syntax errors if it does not meet the requirements of a copy statement. This happens even if there is not a space character prior to the "COPY" text, which is required by the language specification.
Problem conclusion
The real time syntax parser for COBOL will now only treat the word COPY as the start of a copy statement if the character preceding it is a space. The problem listed in this APAR has been resolved with IBM Rational Developer for System z V8.5.1.5 Fix Pack which is available from the Recommended Fixes support download page: http://www-1.ibm.com/support/docview.wss?rs=2294&uid=swg27006335
Temporary fix
Comments
APAR Information
APAR number
PI06264
Reported component name
RATL DEV FOR SY
Reported component ID
5724T0700
Reported release
850
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-11-15
Closed date
2014-06-27
Last modified date
2014-06-27
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL DEV FOR SY
Fixed component ID
5724T0700
Applicable component levels
R851 PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSTRMM","label":"IBM Developer for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"850","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
14 October 2021