A fix is available
APAR status
Closed as program error.
Error description
With CICS TS 5.4 and 5.5 onward, DFH0STAT fails with an ABENDAEIP when a customer uses the Hourglass product to adjust the time backward, due to DFH0STAT attempting to format a negative time value. This started occurring because of the use of the EXEC CICS EXTRACT STATISTICS LASTRESETABS command in DFH0STAT. LASTRESETABS was introduced in CICS TS 5.4. This APAR will change DFH0STAT so that it does not attempt to format a negative time value and so avoid the abend.
Local fix
Modify DFH0STAT to not issue the failing EXTRACT command.
Problem summary
**************************************************************** * USERS AFFECTED: All CICS users * **************************************************************** * PROBLEM DESCRIPTION: DFH0STAT ABENDs AEIP when the elapsed * * time calculated by subtracting the last * * statistical reset time from the current * * time is negative. * **************************************************************** DFH0STAT ABENDs AEIP when receiving INVREQ in an attempt to use FORMATTIME with a negative time value. The elapsed time calculated by subtracting the last statistics reset time from the current time can be negative after a clock change or when running with a simulated date and time as may be provided by HOURGLASS or a similar product.
Problem conclusion
DFH0STAT and DFH0STSY are amended to assume an elapsed time of zero when the calculated time is negative. This will avoid the AEIP ABEND but statistical values that rely on the elapsed time since the last reset, for example counts per second, will be unreliable.
Temporary fix
Comments
APAR Information
APAR number
PH21109
Reported component name
CICS TS Z/OS V5
Reported component ID
5655Y0400
Reported release
200
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-01-16
Closed date
2020-03-23
Last modified date
2020-04-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI68562
Modules/Macros
DFH0STAT DFH0STSY
Fix information
Fixed component name
CICS TS Z/OS V5
Fixed component ID
5655Y0400
Applicable component levels
R201 PSY UI68562
UP20/03/24 P F003
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.5","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.5","Edition":"","Line of Business":{"code":"","label":""}}]