Error description

  • This release includes the following bug fixes:
    1. The Db2 subsystem cloning RESTORE-FROM-DUMPTAPES job brings
    the entire system down due to ENQ problems
    2. CKZ0708A Internal Error, RC=X'00000008, RS=X'00000000,
    INFO=DISPLAY GROUP is bad
    3. Fix the description of the CATWORK-DSN option of the COPY
    command in the user guide
    4. Application cloning does not work with EMC SNAP versions
    newer than 8.0.0
    5. CKZ50013W Completed, with Warnings, RC=X'00000004,
    RS=X'00000000 issued without additional detailed messages
    6. Detect object translation conflicts in DATABASE and CREATOR
    names for indexes
    7. Use the REPAIR utility to resolve RBA format mismatches in
    scenarios with DATA-MOVER PGMs SRCIMCPY and SRCVSCPY
    8. Return code is not passed through after failed validation for
    TEMPLATE-SYSREC-DDN in the source job
    9. Use UR isolation level in SELECT statements from
    SYSIBM.SYSDUMMY1
    10. Change the logic for when error message CKZ203E is displayed
    in the ISPF UI so that job generation does not need to be
    repeated
    11. Fix abend CODE=978 REASON CODE=00000004 when index data sets
    are migrated
    12. Miscellaneous Log Apply bug fixes
    3. Possible infinite loop when COPY-BY-DS is used and there are
    erroneous entries in source catalogs
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Db2 Cloning Tool for z/OS           *
    ****************************************************************
    * PROBLEM DESCRIPTION: The Db2 subsystem cloning               *
    *                      RESTORE-FROM-DUMPTAPES job brings the   *
    *                      entire system down due to ENQ problems. *
    *                                                              *
    *                      CKZ0708A Internal Error, RC=X'00000008, *
    *                      RS=X'00000000, INFO=DISPLAY GROUP is    *
    *                      bad                                     *
    *                                                              *
    *                      Fix the description of the CATWORK-DSN  *
    *                      option of the COPY command in the user  *
    *                      guide.                                  *
    *                                                              *
    *                      Application cloning does not work with  *
    *                      EMC SNAP versions newer than 8.0.0.     *
    *                                                              *
    *                      CKZ50013W Completed, with Warnings,     *
    *                      RC=X'00000004, RS=X'00000000 issued     *
    *                      without additional detailed messages.   *
    *                                                              *
    *                      Detect object translation conflicts in  *
    *                      DATABASE and CREATOR names for indexes. *
    *                                                              *
    *                      Use the REPAIR utility to resolve RBA   *
    *                      format mismatches in scenarios with     *
    *                      DATA-MOVER PGMs SRCIMCPY and SRCVSCPY.  *
    *                                                              *
    *                      Return code is not passed through after *
    *                      failed validation for                   *
    *                      TEMPLATE-SYSREC-DDN in the source job.  *
    *                                                              *
    *                      Use UR isolation level in SELECT        *
    *                      statements from SYSIBM.SYSDUMMY1.       *
    *                                                              *
    *                      Change the logic for when error message *
    *                      CKZ203E is displayed in the ISPF UI so  *
    *                      that job generation does not need to be *
    *                      repeated.                               *
    *                                                              *
    *                      Fix abend CODE=978 REASON CODE=00000004 *
    *                      when index data sets are migrated.      *
    *                                                              *
    *                      Miscellaneous Log Apply bug fixes.      *
    *                                                              *
    *                      Possible infinite loop when COPY-BY-DS  *
    *                      is used and there are erroneous entries *
    *                      in source catalogs.                     *
    ****************************************************************
    * RECOMMENDATION: Apply the PTF.                               *
    *                                                              *
    *                 Attention:                                   *
    *                 If using Db2 subsystem cloning with the      *
    *                 RESTORE-FROM-DUMPTAPES command, users must   *
    *                 apply OA56873 APAR for z/OS and this Db2     *
    *                 Cloning Tool PTF to prevent ENQ problems     *
    *                 that might cause a system failure.           *
    ****************************************************************
    .
    

Problem conclusion

  • Apply the PTF
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH20535

  • Reported component name

    DB2 CLONING TOO

  • Reported component ID

    5655N1000

  • Reported release

    320

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-12-19

  • Closed date

    2020-01-28

  • Last modified date

    2020-02-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI67604

Modules/Macros

  • CKZ#A001 CKZ#ACIR CKZ#ACIW CKZ#ACON CKZ#ACRD CKZ#ACUP CKZ#ADIS
    CKZ#ADSC CKZ#AEXT CKZ#AFMT CKZ#AFRR CKZ#ALLO CKZ#AMIN CKZ#ASYS
    CKZ#AUMX CKZ#AUTO CKZ#BIND CKZ#CARD CKZ#CHKR CKZ#CL   CKZ#CL64
    CKZ#CL7  CKZ#CL8  CKZ#CLLS CKZ#CMTS CKZ#CN64 CKZ#CNTL CKZ#CNVT
    CKZ#CPM  CKZ#CPNT CKZ#CPOL CKZ#DB2V CKZ#DCAT CKZ#DSAF CKZ#DSPL
    CKZ#DSQL CKZ#DYNL CKZ#ENCR CKZ#ENQS CKZ#ENVF CKZ#EPRI CKZ#FCPY
    CKZ#HTAB CKZ#ICAI CKZ#ICAL CKZ#ICCC CKZ#ICCI CKZ#IDCF CKZ#IDSA
    CKZ#IERR CKZ#IHSA CKZ#IKPL CKZ#IKPN CKZ#ILGP CKZ#ILRA CKZ#ILRS
    CKZ#ILSA CKZ#INIT CKZ#IOPF CKZ#IPIE CKZ#IPPB CKZ#IPPC CKZ#IPPD
    CKZ#IPPH CKZ#IPPL CKZ#IPPN CKZ#IPPS CKZ#IRPL CKZ#ISNA CKZ#JPRI
    CKZ#JU64 CKZ#JUST CKZ#LGAA CKZ#LGAC CKZ#LGAF CKZ#LGAI CKZ#LGAP
    CKZ#LGRN CKZ#LIKE CKZ#LOGR CKZ#LRD6 CKZ#MAIN CKZ#MDRV CKZ#MLOG
    CKZ#MMGR CKZ#MPRI CKZ#MREP CKZ#MTIO CKZ#OPRI CKZ#OS   CKZ#OUT2
    CKZ#PARS CKZ#PRNG CKZ#QCAT CKZ#QSAM CKZ#RANG CKZ#RCAT CKZ#REPO
    CKZ#RESM CKZ#RH   CKZ#RH10 CKZ#RM24 CKZ#RPRP CKZ#RUNT CKZ#SQL2
    CKZ#SQLC CKZ#STAT CKZ#STCK CKZ#STMT CKZ#SUBD CKZ#SUBS CKZ#SUBX
    CKZ#SYSC CKZ#TB   CKZ#TB7  CKZ#TB8  CKZ#TP   CKZ#TP10 CKZ#TSS
    CKZ#TSSA CKZ#TUTL CKZ#UCBS CKZ#UPRI CKZ#UTLB CKZ#UTLC CKZ#UTLS
    CKZ#UTOP CKZ#VERS CKZ#VSA1 CKZ#VSA2 CKZ#VSAM CKZ#WRIT CKZ#XMLD
    CKZ#XMLJ CKZ#XMLS CKZ$ACCS CKZ$ACES CKZ$BDSN CKZ$BMSG CKZ$BOOT
    CKZ$BUTJ CKZ$CAF  CKZ$CAFA CKZ$CALL CKZ$CTCM CKZ$DCMD CKZ$DCVT
    CKZ$ERR  CKZ$ESTA CKZ$GSKB CKZ$INFO CKZ$LOG  CKZ$MEPL CKZ$PRFD
    CKZ$PRFR CKZ$SMSG CKZ$SPRM CKZ$SQL2 CKZ$SQLC CKZ$SSCT CKZ$TOK
    CKZ$TSOC CKZ$ZPAR CKZ00020 CKZ00021 CKZ00023 CKZ00066 CKZ00070
    CKZ00071 CKZ00072 CKZ00073 CKZ00500 CKZ00501 CKZ00505 CKZ00506
    CKZ00510 CKZ00520 CKZ00525 CKZ00526 CKZ00527 CKZ00528 CKZ00529
    CKZ00530 CKZ00532 CKZ00533 CKZ00534 CKZ00535 CKZ00536 CKZ00537
    CKZ00538 CKZ00539 CKZ00540 CKZ00541 CKZ00542 CKZ00543 CKZ00544
    CKZ00545 CKZ00546 CKZ00547 CKZ00548 CKZ00549 CKZ00550 CKZ00551
    CKZ00552 CKZ00553 CKZ00554 CKZ00555 CKZ00556 CKZ00560 CKZ00561
    CKZ00562 CKZ00563 CKZ00564 CKZ00565 CKZ00566 CKZ00567 CKZ00569
    CKZ00573 CKZ00574 CKZ00575 CKZ00600 CKZ00602 CKZ00610 CKZ00611
    CKZ00612 CKZ00613 CKZ00616 CKZ00619 CKZ00620 CKZ00621 CKZ00622
    CKZ00624 CKZ00631 CKZ00640 CKZ00669 CKZ00670 CKZ00671 CKZ00672
    CKZ00674 CKZ00677 CKZ00680 CKZ00708 CKZ00709 CKZ00710 CKZ00711
    

Fix information

  • Fixed component name

    DB2 CLONING TOO

  • Fixed component ID

    5655N1000

Applicable component levels

  • R320 PSY UI67604

       UP20/01/30 P F001

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUUE","label":"IBM Db2 Cloning Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: