Error description

  • SMF 72 records contain abnormally high values for CPU time
    for Mobile transactions.  Customer was getting messages like
    "MOBILE CPU DATA EXCEEDS PRODUCT USAGE."  It was discovered
    that IMS did a Delta calculation correctly for TIMEONCP, but
    did not do it correctly for CPUTIME.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All IMS V15 users.                                           *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * IMS is providing an incorrect value for CPUTIME for MVS      *
    * service IWM4MNTF (notify of work).                           *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Install corrective for APAR/PTF                              *
    ****************************************************************
    CPUTIME contains the total CPU time for the current work
    request.  IMS is not resetting the value at each new work
    request.  Instead it contains the total CPU time since the TCB
    was created.
    
    The CPUTIME is used by the Resouce Measurment Facility (RMF) to
    monitor workload activity.  RMF is writing System Management
    Facility (SMF) record 72 subtype 3 to report the CPUTIME.
    

Problem conclusion

  • IMS is modified to calculate CPUTIME for each work request.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH18676

  • Reported component name

    IMS V15

  • Reported component ID

    5635A0600

  • Reported release

    500

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-10-30

  • Closed date

    2020-04-13

  • Last modified date

    2020-05-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI68988

Modules/Macros

  • DFSTMS00
    

Fix information

  • Fixed component name

    IMS V15

  • Fixed component ID

    5635A0600

Applicable component levels

  • R500 PSY UI68988

       UP20/04/16 P F004

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSEPH2","label":"IMS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"15","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
22 December 2023