IBM Support

PH18232: ABENDS0C4 IN GJEIC38X WHEN THRESHOLD PROCESSING HAS BEEN ACTIVATED

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • IMS CTX TCB can cause ABENDS0C4 in GJEIC38x when threshold
    processing has been activated with the following command for
    Sysplex Manager server:
    F Serv-Jobname,THRESH START
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IMS Sysplex manager.            *
    ****************************************************************
    * PROBLEM DESCRIPTION: IMS CTX TCB can cause ABENDS0C4 in      *
    *                      GJEIC38x when threshold processing has  *
    *                      been activated.                         *
    ****************************************************************
    * RECOMMENDATION: Apply the PTF that corrects this APAR.       *
    ****************************************************************
    When IMS system is running with FP=N and LSO=S parameters, the
    IMS system creates DFSXC00 blocks into the extended private area
    of DLI SAS address space. Since Sysplex Manager accessed the
    storage area in IMS control region address space instead of DLI
    SAS address space to refer to DFSXC00 blocks for the threshold
    processing, the ABENDS0C4 in GJEIC38x occurred.
    

Problem conclusion

  • Sysplex Manager improperly refers to DFSXC00 blocks to gather
    the information of PI locks even though IRLM is used as a lock
    manager.
    The following modules have been changed not to refer to DFSXC00
    blocks when IRLM is uses as a lock manager:
     - GJEIC35x
     - GJEIC36x
     - GJEIC37x
     - GJEIC38x
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH18232

  • Reported component name

    IMS SYSPLEX MGR

  • Reported component ID

    5655P0100

  • Reported release

    130

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-10-17

  • Closed date

    2020-03-03

  • Last modified date

    2020-04-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI68167

Modules/Macros

  • GJEIC35E GJEIC35F GJEIC36E GJEIC36F GJEIC37E GJEIC37F GJEIC38E
    GJEIC38F
    

Fix information

  • Fixed component name

    IMS SYSPLEX MGR

  • Fixed component ID

    5655P0100

Applicable component levels

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8AA","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.3.0"}]

Document Information