A fix is available
APAR status
Closed as program error.
Error description
The IIDR CDC for z/OS Meta-data VSAM cluster has SHROPTIONS(3,3) coded. This permits shared use of the cluster between different FailOver instances, but does not provide protection should there be any possiblity of overlapping accesses between different instances. Given the purpose and use of the Meta-data VSAM cluster, such overlapping accesses are not expected to occur. This window of opportunity should be eliminated.
Local fix
Until a permanent resolution is provided, this issue can be avoided by allocating a DD:CHCMTDTA VSAM cluster for each instance being used in a FailOver configuration. If the name of the VSAM cluster contains the &SYSNAME system symbol, a single JCL procedure can be used to allocate the corresponding cluster for each instance. This will require that any Alerts and Alarms settings be made on one system, and then the contents of that system's DD:CHCMTDTA VSAM cluster be copied over to the other cluster(s). Once a resolving PTF is available, this local fix can be abandoned, and the use of a single DD:CHCMTDTA VSAM cluster restored.
Problem summary
**************************************************************** * USERS AFFECTED: Users of IIDR CDC for z/OS who configure it * * to run in a FailOver configuration. * **************************************************************** * PROBLEM DESCRIPTION: The DD:CHCMTDTA VSAM cluster is used by * * multiple instances of IIDR CDC for z/OS * * in a FailOver configuration. Although * * they do not access the VSAM cluster * * concurrently, incidents of corruption * * of the VSAM cluster have occurred. A * * means of serializing access to the VSAM * * cluster is required. * **************************************************************** * RECOMMENDATION: APPLY CORRECTIVE SERVICE * **************************************************************** The DD:CHCMTDA VSAM cluster may be corrupted in a FailOver configuration.
Problem conclusion
The VSAM SHAREOPTIONS for the DD:CHCMTDTA VSAM cluster have been changed from (3,3) to (2,3), and serialization services are now used when accessing the data in the VSAM cluster.
Temporary fix
Comments
APAR Information
APAR number
PH18199
Reported component name
INFO SRVR CDC Z
Reported component ID
5655U7600
Reported release
A21
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-10-17
Closed date
2021-04-05
Last modified date
2021-05-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI74769
Modules/Macros
CHCATHDL CHCATHSW CHCDB2DL CHCDFMTD CHCDSCDB CHCDSCPF CHCPAAUT CHCPALDL CHCPALGP CHCPALIQ CHCPALMD CHCPALMS CHCPALOG CHCPALPF CHCPALRP CHCPALUT CHCRSSSV CHCRSSSW HCHCA21J
Fix information
Fixed component name
INFO SRVR CDC Z
Fixed component ID
5655U7600
Applicable component levels
RA21 PSY UI74769
UP21/04/13 P F104
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTVMA","label":"InfoSphere Data Replication for DB2 for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.2.1"}]
Document Information
Modified date: