A fix is available
APAR status
Closed as program error.
Error description
Users may experience dumps for ABND=0E0 when shutting down started task for IBM Security Guardium S-TAP for DB2 on z/OS with PH09044 applied. ABEND0C4 in APPLICATION when stopping CQM/S-TAP.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IBM DB2 Data Common * * Collector for z/OS * * * **************************************************************** * PROBLEM DESCRIPTION: ABEND0E0-31 when collecting data with * * IBM Security Guardium S-TAP for DB2 on * * z/OS. * **************************************************************** * RECOMMENDATION: APPLY the PTF. * **************************************************************** Problem detected during shutdown of the STAP address space when DB2 data is still in the process of collecting data.
Problem conclusion
Corrected problem collecting data during STAP shutdown. Search Keywords: ABEND0E0
Temporary fix
Comments
×**** PE19/08/26 FIX IN ERROR. SEE APAR PH16080 FOR DESCRIPTION
APAR Information
APAR number
PH13178
Reported component name
COMMON COLLECTO
Reported component ID
5639OLC00
Reported release
110
Status
CLOSED PER
PE
YesPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-06-10
Closed date
2019-07-02
Last modified date
2020-12-09
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI64024
Modules/Macros
CQCMABA1 CQCMABB1 CQCMABC1 CQCMABC5 CQCMB2A1 CQCMB2B1 CQCMB2C5 CQCMBNA1 CQCMBNB1 CQCMBNC5 CQCMBRA1 CQCMBRB1 CQCMBRC1 CQCMBRC5 CQCMC1A1 CQCMC1B1 CQCMC1C1 CQCMC1C5 CQCMC2A1 CQCMC2B1 CQCMC2C1 CQCMC2C5 CQCMCMA1 CQCMCMB1 CQCMCMC1 CQCMCMC5 CQCMCNA1 CQCMCNB1 CQCMCNC1 CQCMCNC5 CQCMCOA1 CQCMCOB1 CQCMCOC1 CQCMCOC5 CQCMCRA1 CQCMCRB1 CQCMCRC1 CQCMCRC5 CQCMCXA1 CQCMCXB1 CQCMCXC1 CQCMCXC5 CQCMESA1 CQCMESB1 CQCMESC1 CQCMESC5 CQCMLCA1 CQCMLCB1 CQCMLCC1 CQCMLCC5 CQCMLRA1 CQCMLRB1 CQCMLRC1 CQCMLRC5 CQCMPRA1 CQCMPRB1 CQCMPRC1 CQCMPRC5 CQCMR1A1 CQCMR1B1 CQCMR1C1 CQCMR1C5 CQCMRLA1 CQCMRLB1 CQCMRLC1 CQCMRLC5 CQCMRRA1 CQCMRRB1 CQCMRRC1 CQCMRRC5 CQCMSIA1 CQCMSIB1 CQCMSIC1 CQCMSIC5 CQCMSRA1 CQCMSRB1 CQCMSRC1 CQCMSRC5 CQCMT1A1 CQCMT1B1 CQCMT1C1 CQCMT1C5 CQCMTPA1 CQCMTPB1 CQCMTPC1 CQCMTPC5 CQCMTRA1 CQCMTRB1 CQCMTRC1 CQCMTRC5 CQCMUGA1 CQCMUGB1 CQCMUGC1 CQCMUGC5 CQCMZBA1 CQCMZBB1 CQCMZBC1 CQCMZBC5 CQCTEDA1 CQCTEDB1 CQCTEDC1 CQCTEDC5 CQCTXLA1 CQCTXLB1 CQCTXLC1 CQCTXLC5
Fix information
Fixed component name
COMMON COLLECTO
Fixed component ID
5639OLC00
Applicable component levels
R110 PSY UI64024
UP19/07/11 P F907
Fix is available