IBM Support

PH07785: TOSI CUMULATIVE FIXES FOR TOOLS BASE 1.6

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • This APAR fixes the following issues of TOSI.
    
    * Forward-Fit of PI84060: IMS command authorization checking is
    not effective on TOSI under ORF jobs when RACFCHK=YES is
    configured.
    * Forward-Fit of PI90093: IMS command authorization checking is
    not effective on TOSI when uisng IMS DBCTL.
    
    This fix requires restarting IMS to reflect changes.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IMS Tools Online System         *
    *                 Interface in IBM Tools Base V1.6             *
    *                 (FMID=HAHN160).                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: This APAR resolves the following issues *
    *                      of IMS Tools Online System Interface.   *
    *                      - Forward fit of Tools Base V1.5 APAR   *
    *                        PI84060.                              *
    *                      - Forward fit of Tools Base V1.5 APAR   *
    *                        PI90093.                              *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    This APAR resolves the following issues of IMS Tools Online
    System Interface.
    - Forward fit of Tools Base V1.5 APAR PI84060.
      TOSI should check whether a caller job have sufficient
      authority to run IMS commands when RACFCHK=YES is configured.
      However, it isn't effective properly for ORF jobs.
      Also, RCLASS= parameter which specifies an identifier for RACF
      resource classes for IMS hasn't been applied for IMS command
      authorization checking on TOSI.
    
    - Forward fit of Tools Base V1.5 APAR PI90093.
      TOSI should check whether a caller job have sufficient
      authority to run IMS commands when RACFCHK=YES is configured.
      However, it isn't effective properly when one of the following
      conditions is met.
      - Using IMS DBCTL.
      - RCF=T or RCF=N is specified in DFSPBxxx member.
    

Problem conclusion

  • The following TOSI modules have been changed to fix the above
    problem:
    - FOIITK0D, FOIITK0E, FOIITK0F
    - FOICCON0, FOICIVP0, FOICQGR0, FOICRBU0, FOICREQ0, FOICRSP0
    - FOICSAFI
    
    +--------------------------------------------------------------+
    |To make this maintenance effective, you must restart IMS      |
    |control region.                                               |
    +--------------------------------------------------------------+
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH07785

  • Reported component name

    IMS TOOLS BASE

  • Reported component ID

    5655V9300

  • Reported release

    160

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-01-29

  • Closed date

    2019-03-25

  • Last modified date

    2019-04-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI62090

Modules/Macros

  • FOICCON0 FOICIVP0 FOICQGR0 FOICRBU0 FOICREQ0 FOICRSP0 FOICSAFI
    FOIITK0D FOIITK0E FOIITK0F HKTQLINK
    

Fix information

  • Fixed component name

    IMS TOOLS BASE

  • Fixed component ID

    5655V9300

Applicable component levels

  • R160 PSY UI62090

       UP19/03/27 P F903

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCJN3E","label":"IBM Tools Base"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"160"}]

Document Information

Modified date:
19 October 2020