APAR status
Closed as program error.
Error description
When an invalid IMS type 1 command is issued from SM ISPF, IMS component can abend with ABENDU0729 in DFSSPM00.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IMS Sysplex manager. * **************************************************************** * PROBLEM DESCRIPTION: IMS control region component of Sysplex * * Manager can fail with ABENDU0729 in * * DFSSPM00. * **************************************************************** * RECOMMENDATION: Apply the PTF that corrects this APAR. * **************************************************************** When an incorrect IMS type-1 command is issued from Sysplex Manager user interface, IMS control region component of Sysplex Manager can break a base register which has an address of an internal buffer pool. In this case, ABENDU0729 in DFSSPM00 can occur for releasing the internal buffer pool.
Problem conclusion
Sysplex Manager has been changed not to break a base register which has an address of the internal buffer.
Temporary fix
Comments
APAR Information
APAR number
PH05303
Reported component name
IMS SYSPLEX MGR
Reported component ID
5655P0100
Reported release
130
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-11-14
Closed date
2018-12-04
Last modified date
2019-01-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI60067
Modules/Macros
GJEICMDD GJEICMDE GJEICMDF
Fix information
Fixed component name
IMS SYSPLEX MGR
Fixed component ID
5655P0100
Applicable component levels
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8AA","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.3.0"}]