IBM Support

PH03611: THE BIND SCRIPTS FOR DB2 VERSION 12 MUST INCLUDE THE DBRM MODULES FOR BOTH DB2 VERSION 12 AND VERSION 11

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Before applying this fix, the required DBRM modules for Db2
    Version 11 were not included in bind jobs for Db2 Version 12
    (CURRENT FUNCTION LEVEL(V12R1M100)) for Db2 Cloning Tool
    Table Space Cloning. As a result, users might encounter
    error the message 'CKZ61325W SQL Error in Module CKZ06221
    DSNT408I SQLCODE = -805, ERROR' in the source job.
    After applying this fix, the required Db2 Version 11 DBRM
    modules are included in the bind scripts for Db2 Version 12
    and users should no longer see the CKZ06221 error in the source
    job.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IBM Db2 Cloning Tool z/OS.          *
    ****************************************************************
    * PROBLEM DESCRIPTION: Before applying this fix, the required  *
    *                      DBRM modules for Db2 Version 11 were    *
    *                      not included in bind jobs for Db2       *
    *                      Version 12 (CURRENT FUNCTION LEVEL      *
    *                      (V12R1M100)) for Db2 Cloning Tool       *
    *                      Table Space Cloning. As a result,       *
    *                      users might encounter error the         *
    *                      message 'CKZ61325W SQL Error in Module  *
    *                      CKZ06221 DSNT408I SQLCODE = -805,       *
    *                      ERROR' in the source job.               *
    *                      After applying this fix, the required   *
    *                      Db2 Version 11 DBRM modules are         *
    *                      included in the bind scripts for Db2    *
    *                      Version 12 and users should no longer   *
    *                      see the CKZ06221 error in the source    *
    *                      job.                                    *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH03611

  • Reported component name

    DB2 CLONING TOO

  • Reported component ID

    5655N1000

  • Reported release

    320

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-10-03

  • Closed date

    2018-10-12

  • Last modified date

    2018-11-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    CKZCALNC
    

Fix information

  • Fixed component name

    DB2 CLONING TOO

  • Fixed component ID

    5655N1000

Applicable component levels

  • R320 PSY UI59086

       UP18/10/16 P F810

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUUE","label":"IBM Db2 Cloning Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: