Error description
Batch Server service's Logon As Id was being authenticated when processing projects, especially when a project(s) in IBM AD was available only via ACL access (non-Public). If the Batch Server's ID was not entered and configured for ACL access for the project in IBM AD's Configuration Server, then Batch Server would not have access to the project, and would not process it.
Local fix
The (all uppercase) unqualified machine name followed by a "$" symbol, e.g. MYHOST$, followed by the Windows domain name specified on the System can be entered in Configuration Server and given access to workspaces like other users, if the Batch Server service is using Local System Account to log on. After that, restart Batch Server service, and it will process the waiting projects.
Problem summary
Batch Server service's ID was being authenticated for project access, which caused Batch Server to not process projects if Batch Server service's ID was not configured explicitly in IBM AD Configuration Server for projects only accessible via ACL.
Problem conclusion
IBM AD code was changed to not authenticate Batch Server's service ID against ACLs for processing projects.
Temporary fix
Comments
APAR Information
APAR number
PH02372
Reported component name
APPL DISCOVERY
Reported component ID
5737B1600
Reported release
505
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-08-31
Closed date
2018-09-04
Last modified date
2018-09-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
CCS
Fix information
Fixed component name
APPL DISCOVERY
Fixed component ID
5737B1600
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSRR9Q","label":"IBM Application Discovery for IBM Z"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"505","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
04 September 2018