PH02088: NO WAY TO RETRIEVE PANEL HAA$PRV AFTER "Y" IS SELECTED

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When viewing a HAA V4.2 profile in HAA V4.3, the following
    HAA$PRV panel is displayed:
    ------------------
    Profile: TS6438.HAA-4521 on DB1A(RS22)
    This profile was created with a previous version of Automation
    Tool.
    Once this profile is saved, it will become incompatible with
    earlier versions of Automation Tool.
    To preserve this profile, you may cancel from this screen and
    export this profile using a new name and/or creator.
    
            Do not show this panel again  N (Y - Yes, N - No)
    
               Press ENTER to process or PF3 to Cancel
    -----------------
    Problem: When you enter "Y" to NOT show the panel again, there
    is no way to display the panel again.
    Solution: Re-displaying profile conversion warning panel by
    using command "RESET HAA$PRV" on HAA$MAIN panel.
    Expected Result: After entering "RESET HAA$PRV" command on
    HAA$MAIN panel a warning message - "HAA658I - Warning panel
    HAA$PRV will now be redisplayed." is displayed and it
    retreives HAA$PRV after "Y" is selected.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IBM Db2 Automation Tool z/OS.       *
    ****************************************************************
    * PROBLEM DESCRIPTION: When viewing a HAA V4.2 profile in HAA  *
    *                      V4.3, the following HAA$PRV panel is    *
    *                      displayed:                              *
    *                      ------------------                      *
    *                      Profile: TS6438.HAA-4521 on DB1A(RS22)  *
    *                      This profile was created with a         *
    *                      previous version of Automation          *
    *                      Tool. Once this profile is saved, it    *
    *                      will become incompatible with           *
    *                      earlier versions of Automation Tool.    *
    *                      To preserve this profile, you may       *
    *                      cancel from this screen and export      *
    *                      this profile using a new name and/or    *
    *                      creator.                                *
    *                               Do not show this panel again   *
    *                        N (Y - Yes, N - No)                   *
    *                                 Press ENTER to process or    *
    *                        PF3 to Cancel                         *
    *                      -----------------                       *
    *                      Problem: When you enter "Y" to NOT      *
    *                      show the panel again, there is no way   *
    *                      to display the panel again.             *
    *                      Solution: Re-displaying profile         *
    *                      conversion warning panel by using       *
    *                      command "RESET HAA$PRV" on HAA$MAIN     *
    *                      panel. Expected Result: After entering  *
    *                      "RESET HAA$PRV" command on HAA$MAIN     *
    *                      panel a warning message - "HAA658I -    *
    *                      Warning panel HAA$PRV will now be       *
    *                      redisplayed." is displayed and it       *
    *                      retreives HAA$PRV after "Y" is s        *
    *                      elected.                                *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH02088

  • Reported component name

    DB2 AUTOMATION

  • Reported component ID

    5697G6300

  • Reported release

    430

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-08-23

  • Closed date

    2018-10-18

  • Last modified date

    2018-11-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    HAABND2
    

Fix information

  • Fixed component name

    DB2 AUTOMATION

  • Fixed component ID

    5697G6300

Applicable component levels

  • R430 PSY UI59242

       UP18/10/27 P F810

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUWB","label":"IBM Db2 Automation Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.3.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.3.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
12 February 2021