APAR status
Closed as program error.
Error description
ABENDS0C1-01 in GJEOMOP0
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IMS Sysplex manager. * **************************************************************** * PROBLEM DESCRIPTION: ABENDS0C1 and ABENDS0C4 can occur in * * IMS OM output user exit, GJEOMOP0. * **************************************************************** * RECOMMENDATION: Apply the PTF that corrects this APAR. * **************************************************************** When an IMS type 2 command is issued from SM ISPF UI, it can trigger issuing an unsolicited message such as DFS2864I EXTERNAL TRACE DATASET DFSTRA01 FULL - SWITCHING TO DFSTRA02 from an IMS control region. In this case, IMS OM output user exit, GJEOMOP0, is scheduled for an OM command response and for an unsolicited message in parallel with multiple tasks. Since GJEOMOP0 has incomplete logic for running in parallel, ABENDS0C1 can occur. In addition to that, GJEOMOP0 has incomplete logic for releasing own output buffers, ABENDS0C4 can occur.
Problem conclusion
Install the APAR to avoid ABENDS0C1 and ABENDS0C4 in GJEOMOP0.
Temporary fix
Comments
APAR Information
APAR number
PH01066
Reported component name
IMS SYSPLEX MGR
Reported component ID
5655P0100
Reported release
130
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-07-30
Closed date
2018-10-12
Last modified date
2019-05-09
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI59078
Modules/Macros
GJEOMOP0
Fix information
Fixed component name
IMS SYSPLEX MGR
Fixed component ID
5655P0100
Applicable component levels
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8AA","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.3.0"}]
Document Information
Modified date:
24 June 2022