IBM Support

PI21670: DB2 ADMINISTRATION TOOL FOR Z/OS ON PANEL ADB26DT THE INPUT IS NOT RECOGNIZED WHEN OVERWRITING A PREVIOUS VALUE (LIKE 'NO')

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • DB2 Administration Tool for z/OS on panel ADB26DT the input is
    not recognized when overwriting a previous value (like 'NO')
    with just the first letter of the desired command
    (in case of 'Y' for 'YES' leaving 'YO') in the YES/NO prompt.
     This works on other panels, like ADB2RT.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of the DB2 Administration Tool for     *
    *                 z/OS who use panel ADB26DT 'Drop Table' to   *
    *                 drop a table.                                *
    ****************************************************************
    * PROBLEM DESCRIPTION: When dropping a table using panel       *
    *                      ADB26DT and specifying 'NO' for the     *
    *                      field 'Report Drop Impacts', and        *
    *                      pressing the Enter key on the next      *
    *                      panel, then pressing the F3 key to      *
    *                      return to panel ADB26DT without         *
    *                      any change, and entering a 'Y' over     *
    *                      the 'NO' on the 'Report Drop Impacts'   *
    *                      field, an invalid value of 'YO' is      *
    *                      generated for the field.                *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    When dropping a table using panel ADB26DT and specifying 'NO'
    for the field 'Report Drop Impacts', and pressing the Enter
    key on the next panel, then pressing the F3 key to return to
    panel ADB26DT without any change, and entering a 'Y' over the
    'NO' on the 'Report Drop Impacts' field, an invalid value of
    'YO' is generated for the field.
    

Problem conclusion

  • Problem has been resolved.
    
    DB2 Admin allows the user to only enter the first character
    (Y/N) in a YES/NO field, and the value will be converted to
    the correct value automatically.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI21670

  • Reported component name

    DB2 ADMIN TOOL

  • Reported component ID

    568851500

  • Reported release

    A20

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2014-07-09

  • Closed date

    2014-09-22

  • Last modified date

    2014-10-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI21539 UI21540

Modules/Macros

  •    ADBPPDCC ADBP6CFR ADB2MES  ADB2MEX  ADB2USC
    ADB2USE  ADB2USK  ADB2USKL ADB2USU  ADB2UXO  ADB26DD  ADB26DS
    ADB26DT
    

Fix information

  • Fixed component name

    DB2 ADMIN TOOL

  • Fixed component ID

    568851500

Applicable component levels

  • RA20 PSY UI21539

       UP14/09/24 P F409

  • RB10 PSY UI21540

       UP14/09/24 P F409

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.2.0"}]

Document Information

Modified date: