APAR status
Closed as program error.
Error description
Worklight upgrader plugin outputs wrong application-descriptor.xml when "android" element specifies a sharedUserId attribute.
Local fix
To fix the problem manually, place the "simpleDataSharing" element, which is a child of the "android" element below the "security" element, like so: <android> <security ... <simpleDataSharing ... </android> Also add a sharedCookies attribute to the simpleDataSharing element, like so: <android> <security ... <simpleDataSharing sharedCookies="" </android>
Problem summary
**************************************************************** * USERS AFFECTED: * * Developers of Worklight projects that are upgraded from * * Worklight Studio versions older than 6.2 up to Worklight * * Studio 6.2 that have an Android environment and declare a * * "sharedUserId" attribute in the "android" XML tag. * **************************************************************** * PROBLEM DESCRIPTION: * * Worklight projects that are upgraded from Worklight Studio * * versions older than 6.2 up to Worklight Studio 6.2 that have * * an Android environment and declare a "sharedUserId" * * attribute in the "android" XML element will result in an * * invalid application-descriptor.xml file. * **************************************************************** * RECOMMENDATION: * * - * ****************************************************************
Problem conclusion
Worklight Studio upgrader plugin now generates proper XML structure in application-descriptor.xml file that conforms to the application-descriptor schema when the "sharedUserId" attribute is present in the "android" XML element.
Temporary fix
Comments
APAR Information
APAR number
PI20141
Reported component name
WORKLIGHT CONSU
Reported component ID
5725I4301
Reported release
506
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-06-16
Closed date
2014-08-29
Last modified date
2014-08-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WORKLIGHT CONSU
Fixed component ID
5725I4301
Applicable component levels
R506 PSY
UP
R600 PSY
UP
R610 PSY
UP
R620 PSY
UP
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSZH4A","label":"IBM Worklight"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"506"}]
Document Information
Modified date: