A fix is available
APAR status
Closed as program error.
Error description
Issue in validation exit when a profile exists multiple times in different data sets PARMGEN VALIDATION
Local fix
Create only one profile with the same independent on their location in data sets. Or create multiple profiles with different names.
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component * * - ICAT and PARMGEN * **************************************************************** * PROBLEM DESCRIPTION: Validation exit for D2 runs in infinite * * loop when new UCONFIG DD name is used * * in $SYSIN. * **************************************************************** * RECOMMENDATION: Apply this PTF. * **************************************************************** PROBLEM SUMMARY: Validation exit for D2 runs in infinite loop when new UCONFIG DD name is used in $SYSIN. PROBLEM CONCLUSION: Validation exit now ignores UCONFIG DD and just looks for profiles that reside in WCONFIG. KEYWORDS: WCONFIG UCONFIG PARMGEN $SYSIN VALIDATION VALIDATE CIRCUMVENTION: Don't use UCONFIG in $SYSIN. TEMPORARY FIX: Don't use UCONFIG in $SYSIN.
Problem conclusion
Validation exit now ignores UCONFIG DD and just looks for profiles that reside in WCONFIG. KEYWORDS: WCONFIG UCONFIG PARMGEN $SYSIN VALIDATION VALIDATE CIRCUMVENTION: Don't use UCONFIG in $SYSIN. TEMPORARY FIX: Don't use UCONFIG in $SYSIN.
Temporary fix
Don't use UCONFIG in $SYSIN.
Comments
APAR Information
APAR number
PI17671
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
520
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-05-12
Closed date
2014-09-02
Last modified date
2014-10-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI21005
Modules/Macros
KD2BHELP KD2CVPG KD2DDICT KD2VERS
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R520 PSY UI21005
UP14/09/09 P F409
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
02 October 2014