Fixes are available
APAR status
Closed as program error.
Error description
When a Java Message Service (JMS) adapter performs a 'read' operation against a JMS broker, a null pointer exception will occur if the message received does not contain the "JMSDestination" field.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Developers (application developers as well as server side * * developers) who administer, test, deploy, or make use of the * * Java Message Service (JMS) adapter in any way. * **************************************************************** * PROBLEM DESCRIPTION: * * Normally when a message is placed onto a message queue, the * * JMSDestination property is populated. In some cases (such as * * when a test message is put on a test queue) the * * JMSDestination field will be null. The Worklight Java * * Message Server (JMS) adapter will throw a Null Pointer * * Exception in these cases. * **************************************************************** * RECOMMENDATION: * * - * ****************************************************************
Problem conclusion
Additional checking is done at runtime to avoid a null pointer exception in the case that the JMS Destination field does not exist.
Temporary fix
Comments
APAR Information
APAR number
PI17180
Reported component name
WORKLIGHT CONSU
Reported component ID
5725I4301
Reported release
610
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-05-01
Closed date
2014-05-15
Last modified date
2014-05-15
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WORKLIGHT CONSU
Fixed component ID
5725I4301
Applicable component levels
R506 PSY
UP
R600 PSY
UP
R610 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSZH4A","label":"IBM Worklight"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date: