A fix is available
APAR status
Closed as program error.
Error description
When DB2 provides portion of trace data that exceeds CRD internal buffer FPEV5009I message is issued as follows : FPEV5009I TDB3 CORRUPTED DB2 RETURN AREA FOUND ... FPEV5009I TDB3 DUMP IS TAKEN. FPEV5009I TDB3 PLEASE FORWARD TO DB2 SUPPORT. FPEV5009I TDB3 RA@ IS '13D8D0C0'x FPEV5009I TDB3 IFCA@ IS '13D8D00C'x FPEV6806I TDB3 REPORT DATA COLLECTION MANAGER IS RESTARTING DB2 TRACE It does not say anything about actual problem reason (CRD internal buffer is too small) and possible solution (increase OPBUFSIZE value) so looks not very helpful and confusing
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component * * - Batch CRD * **************************************************************** * PROBLEM DESCRIPTION: Instrumental message FPEV5009I * * does not reflect a real reason * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** PROBLEM SUMMARY: Instrumental message FPEV5009I does not reflect a real reason PROBLEM CONCLUSION: Change message FPEV5009I to reflect a real reason KEYWORDS: FPEV5009I CRD OPBUFSIZE PARAMETER
Problem conclusion
Change message FPEV5009I to reflect a real reason KEYWORDS: FPEV5009I CRD OPBUFSIZE PARAMETER
Temporary fix
Comments
APAR Information
APAR number
PI15944
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
420
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-04-14
Closed date
2014-07-14
Last modified date
2014-08-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI19567 UI19568 UI19569 UI19570
Modules/Macros
DGOZDB2M
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R420 PSY UI19567
UP14/07/17 P F407
R510 PSY UI19568
UP14/07/17 P F407
R511 PSY UI19569
UP14/07/17 P F407
R520 PSY UI19570
UP14/07/17 P F407
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
04 August 2014