A fix is available
APAR status
Closed as program error.
Error description
Syndicating libraries with items that have failed in another syndication pair does not attempt to syndicate the failed items on update of a new Syn/Sub pair.
Local fix
Click rebuild button instead of update.
Problem summary
Syndicating libraries with items that have failed in another syndication pair does not attempt to syndicate the the failed items on update of a new syndicator and subscriber pair.
Problem conclusion
Failed items were incorrectly being excluded from the update on first syndication, leading to some items not being syndicated, and possible failures during the syndication due to missing items. On first syndication, everything is sent over, as is done with a rebuild. After this point, update will return to its normal behaviour of not re-sending failed items.
Temporary fix
Comments
APAR Information
APAR number
PI15684
Reported component name
LOTUS WEB CONT
Reported component ID
5724I2900
Reported release
800
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-04-09
Closed date
2015-02-01
Last modified date
2015-02-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
LOTUS WEB CONT
Fixed component ID
5724I2900
Applicable component levels
R800 PSY
UP
[{"Business Unit":{"code":null,"label":null},"Product":{"code":"SUPPORT","label":"IBM Worldwide Support"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"800","Edition":"","Line of Business":{"code":null,"label":null}}]
Document Information
Modified date:
10 September 2020