Error description

  • A CCF BMP job ends with RC0 even though there is an error with
    the IMS command and it is not processed.  For example:
    CCF0150I - FOLLOWING RECORD READ FROM: CCFSYSIN:      /DIS ACT
    CCF7413I - COMMAND BEING ROUTED TO PLEX = xxxx:       /DIS ACT
    .
    CCF7426W - CSLOMCMD RECEIVED RC=0200000C RSN=00003008
    DFS009 15:42:02 COMMAND NOT AUTHORIZED AS ENTERED FROM OM API.
    The CCF job ends with RC0.  CCFMOD OPTIONS are
    CCF6010I /CCFMOD OPTIONS ...: MODFAIL=ABEND
    CCF6010I ERRORS .: ABEND=U3999 SETRC=0016
      The CCF job should end with a non-zero return code.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Command Control Facilities V2.2     *
    ****************************************************************
    * PROBLEM DESCRIPTION: Command Control Facility job with       *
    *                      command error ends with RC0.            *
    ****************************************************************
    * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF      *
    ****************************************************************
    A CCF BMP job ends with RC0 even though there is an error with
    the IMS command and it is not processed.  For example:
    CCF0150I - FOLLOWING RECORD READ FROM: CCFSYSIN:      /DIS ACT
    CCF7413I - COMMAND BEING ROUTED TO PLEX = xxxx:       /DIS ACT
    CCF7426W - CSLOMCMD RECEIVED RC=0200000C RSN=00003008
    DFS009 15:42:02 COMMAND NOT AUTHORIZED AS ENTERED FROM OM API.
    The CCF job ends with RC0.  CCFMOD OPTIONS are
    CCF6010I /CCFMOD OPTIONS ...: MODFAIL=ABEND
    CCF6010I ERRORS .: ABEND=U3999 SETRC=0016
      The CCF job should end with a non-zero return code.
    

Problem conclusion

  • This APAR fixes an error where the CCF Command processor runs
    but ends with a Return Code of zero even though an error message
    was issued from the OM API stating that the command was not
    authorized.  For example:
    CCF7426W - CSLOMCMD RECEIVED RC=0200000C RSN=00003008
    DFS009 15:42:02 COMMAND NOT AUTHORIZED AS ENTERED FROM OM API.
    The CCF options GENERAL=SETRC and SETRC=RC are required when a
    command is rejected and a non-Zero Return Code is expected from
    the batch job.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI14391

  • Reported component name

    IMS COMMAND CTL

  • Reported component ID

    5655F4000

  • Reported release

    220

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2014-03-24

  • Closed date

    2015-07-29

  • Last modified date

    2015-08-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI29818

Modules/Macros

  •    CCFIXCF0 H24E220J
    

Fix information

  • Fixed component name

    IMS COMMAND CTL

  • Fixed component ID

    5655F4000

Applicable component levels

  • R220 PSY UI29818

       UP15/07/31 P F507

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCBTY6","label":"IMS Command Control Facility"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.2.0"}]

Document Information

Modified date:
21 October 2020