A fix is available
APAR status
Closed as program error.
Error description
When running COPYCHECK WITHDRAW it is possible to get GCL05647E ANTRQST ERROR; DATA MOVER RETURN CODE=7645 X'1DDD' REASON CODE=4042 X'FA2A' LOC=FW002 There is a small window between the check for FlashCopy relationships on the volumes and when the FlashCopy WITHDRAW is done. If the relationship ends between the check and WITHDRAW the above error will be reported. The ANTRQST return code 7645 should not cause an error to be reported.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS Cloning Tool V1.2 * **************************************************************** * PROBLEM DESCRIPTION: Possible message GCL05647E ANTRQST * * ERROR: DATA MOVER RETURN CODE=7645 * * X'1DDD' REASON CODE=4042 X'FA2A' * * LOC=FW002 * **************************************************************** * RECOMMENDATION: * **************************************************************** When running COPYCHECK WITHDRAW it is possible to get GCL05647E ANTRQST ERROR; DATA MOVER RETURN CODE=7645 X'1DDD' REASON CODE=4042 X'FA2A' LOC=FW002 There is a small window between the check for FlashCopy relationships on the volumes and when the FlashCopy WITHDRAW is done. If the relationship ends between the check and WITHDRAW the above error will be reported. The ANTRQST return code 7645 should not cause an error to be reported.
Problem conclusion
Code has been modified to correct this issue.
Temporary fix
Comments
APAR Information
APAR number
PI14349
Reported component name
IMS CLONING TOO
Reported component ID
5655U9100
Reported release
120
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2014-03-24
Closed date
2014-04-01
Last modified date
2014-05-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI16629
Modules/Macros
GCL00056
| SC19247500 |
Fix information
Fixed component name
IMS CLONING TOO
Fixed component ID
5655U9100
Applicable component levels
R120 PSY UI16629
UP14/04/04 P F404
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCBTY5","label":"IMS Cloning Tool"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.2.0"}]
Document Information
Modified date: