Error description
A deadlock occurs against the GADGET_APPLICATION table.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Administrators who deploy Worklight server on a WebSphere * * Liberty Profile server using the cluster topology as * * detailed in the IBM Worklight v6.1.0 Knowledge Center * * section titled "Setting up IBM Worklight in an IBM WebSphere * * Application Server Liberty Profile farm": * * http://www-01.ibm.com/support/knowledgecenter/SSZH4A_6.1.0/c * * om.ibm.worklight.installconfig.doc/admin/t_setting_up_WL_lib * * erty_8_5_cluster_env.html?lang=en * **************************************************************** * PROBLEM DESCRIPTION: * * Deadlock messages are observed in the Worklight server logs * * for database table GADGET, GADGET_APPLICATION and * * CLUSTER_SYNC due to the incorrect use of OpenJPA * * enhancements for JPA entity classes associated with these * * tables. * **************************************************************** * RECOMMENDATION: * * - * ****************************************************************
Problem conclusion
Code changes are made so that the entity classes are enhanced properly which eliminate the deadlock errors.
Temporary fix
Comments
APAR Information
APAR number
PI12676
Reported component name
WORKLIGHT CONSU
Reported component ID
5725I4301
Reported release
600
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-02-27
Closed date
2014-06-06
Last modified date
2014-06-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WORKLIGHT CONSU
Fixed component ID
5725I4301
Applicable component levels