APAR status
Closed as program error.
Error description
It is assumed that the JSESSIONID either has a value or is null. However, in this error condition, the JSESSIONID is set to an empty string.
Local fix
n/a
Problem summary
**************************************************************** * USERS AFFECTED: WebSphere eXtreme Scale clients that use * * eXtreme Scale HTTP session management and * * splicer property, listenerMode=false * **************************************************************** * PROBLEM DESCRIPTION: The following error occurs: * * CWWSM0004E: Caught a data grid * * exception * * java.util.NoSuchElementException as * * seen in the logs * **************************************************************** * RECOMMENDATION: * **************************************************************** WebSphere eXtreme Scale assumes that a JSESSIONID cookie is either not present (null) or present with a valid session value. However, if an application has set the JSESSIONID to an empty string (or invalid value) (for example, during an application logout), then eXtreme Scale does not handle the unexpected value and produces an exception in the logs.
Problem conclusion
WebSphere eXtreme Scale now handles empty string (and invalid values) for JSESSIONID and no longer produces an exception.
Temporary fix
Comments
APAR Information
APAR number
PI10561
Reported component name
WS EXTREME SCAL
Reported component ID
5724X6702
Reported release
850
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-01-28
Closed date
2014-02-14
Last modified date
2014-02-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WS EXTREME SCAL
Fixed component ID
5724X6702
Applicable component levels
R850 PSY
UP
R860 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSTVLU","label":"WebSphere eXtreme Scale"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"850","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date: