A fix is available
APAR status
Closed as program error.
Error description
MSPLINK macro in SIOHMAC(IOHGEN) is missing parms LCLICON and LCLPLKID, which were added in IMS V12. If an MSC link has been defined in IMS, HP Sysgen receives these error messages: ASMA017W Undefined keyword parameter; default to positional, including keyword - MSPLI/LCLICON ASMA017W Undefined keyword parameter; default to positional, including keyword - MSPLI/LCLPLKID
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of High Performance IMS Sysgen * * v2.2.0 Merge/Clone process. * **************************************************************** * PROBLEM DESCRIPTION: Users of HPSysgen V2.2.0 Merge/Clone * * function receive assembler errors on * * the MSPLINK macro. For example: * * * * ASMA017W Undefined keyword parameter; * * default to positional, including * * including keyword - MSPLI/LCLICON * * * * The HPSysgen IOHGEN macro does not * * have newest parms for MSPLINK macro. * * * **************************************************************** * RECOMMENDATION: * **************************************************************** Users of HPSysgen V2.2.0 Merge/Clone function receive assembler errors if the MSPLINK macro is used. For example: ASMA017W Undefined keyword parameter; default to positional, including keyword - MSPLI/LCLICON IOHGEN macro, used in the Merge/Clone process, does not include the newer LCLICON, LCLPLKID, and NAME2 parameters that are in the MSPLINK macro.
Problem conclusion
IOHGEN macro, used in the Merge/Clone process, is updated by this fix to include the newer LCLICON, LCLPLKID, and NAME2 parameters in its version of the MSPLINK macro.
Temporary fix
Comments
APAR Information
APAR number
PI10258
Reported component name
IMS HP SYSGEN T
Reported component ID
5655F4300
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2014-01-23
Closed date
2014-03-10
Last modified date
2014-04-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI15871
Modules/Macros
IOHGEN
Fix information
Fixed component name
IMS HP SYSGEN T
Fixed component ID
5655F4300
Applicable component levels
R220 PSY UI15871