Error description

  • When database is configured with DDF=NO, incorrect data
    is displayed on Omegamon screens and workspaces for DDF
    and error messages are in log.
    KO2O1958E NO DATA ADDRESS FOUND FOR IFCID CSTA (DPSRMSUB)
    issued every 3 minutes.
    

Local fix

  • set DB2 for z/OS DDF startup option to YES
    or do not use "subsystem management" and corresponding
    situations.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component                           *
    *                 - Classic Interface                          *
    *                 - CUA Interface                              *
    *                 - TEP                                        *
    *                 - Enhanced 3270 UI                           *
    ****************************************************************
    * PROBLEM DESCRIPTION: When database is configured with        *
    *                      DDF=NO, incorrect data is displayed     *
    *                      on Omegamon screens and workspaces      *
    *                      for DDF and error messages are in log.  *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF.                              *
    ****************************************************************
    PROBLEM SUMMARY:
    When database is configured with DDF=NO parameter, database
    does not provide section with DDF data in IFCID 1.
    Omegamon expected to have this section always and could not
    process IFCID 1 data without DDF section correctly.
    
    PROBLEM CONCLUSION:
    Logic in routines has been changed to process IFCID 1 data
    without DDF section and to show N/C, N/P or zero for DDF fields.
    
    KEYWORDS:
    KO2O1958E CSTA DPSRMSUB
    

Problem conclusion

  • Logic in routines has been changed to process IFCID 1 data
    without DDF section and to show N/C, N/P or zero for DDF fields.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI47177

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    511

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-08-19

  • Closed date

    2015-11-06

  • Last modified date

    2017-02-01

  • APAR is sysrouted FROM one or more of the following:

    PI46666

  • APAR is sysrouted TO one or more of the following:

    UI32738 UI32739 UI32740

Modules/Macros

  • KDPINDEX KD2RFVDD KD2RFVSD KD2RHDDD KD2VDDRD KD2VHDRD KD2WDDFD
    KD2WHDFD KO2APCIA KO2APCIK KO2APCIS KO2APCI2 KO2APCJA KO2APCJK
    KO2APCJS KO2APCJ2 KO2APCKA KO2APCKK KO2APCKS KO2APCK2 KO2APCNA
    KO2APCNK KO2APCNS KO2APCN2 KO2APCOA KO2APCOK KO2APCOS KO2APCO2
    KO2CDFSA KO2CDFSK KO2CDFSS KO2CDFS2 KO2ODSTB KO2O225B
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R511 PSY UI32738

       UP15/11/10 P F511

  • R520 PSY UI32739

       UP15/11/10 P F511

  • R530 PSY UI32740

       UP15/11/10 P F511

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
01 February 2017