A fix is available
APAR status
Closed as program error.
Error description
the client's delegate callback methods (i.e. didReceiveResonse, didReceiveData, ...) got called when the server returned HTTP status 401 which will initiate the authorization process. This is not the desired behavior! The client's code shouldn't be aware of the authorization process at all, but only to get notified weither it was failed, or in case it succeeded, get the original resource response, whatever that was. Note that in each callback method below, we check for this flag and if it is set to YES, we won't deliver the event to the client delegate code.
Local fix
Cancel the connection upon start of authorization process
Problem summary
**************************************************************** * USERS AFFECTED: * * Users who use NSURLConnectionDataDelegate accessing secured * * resource and implement didReceiveData * **************************************************************** * PROBLEM DESCRIPTION: * * Part of the authorization flow was exposed to the user's * * delegate, thus corrupting the data. * **************************************************************** * RECOMMENDATION: * * - * ****************************************************************
Problem conclusion
The code was fixed to handle the authorization flow before calling the user's didReceiveData
Temporary fix
Comments
APAR Information
APAR number
PI41467
Reported component name
WL/MFPF CONSUME
Reported component ID
5725I4301
Reported release
700
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-05-20
Closed date
2015-05-31
Last modified date
2015-05-31
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WL/MFPF CONSUME
Fixed component ID
5725I4301
Applicable component levels
R700 PSY
UP