A fix is available
APAR status
Closed as program error.
Error description
UK31434 introduced a change to the collector logic for VTAM classic (panel ZALLT) and Tivoli Enterprise Portal data collection that caused threads in Identify/Signon status to be displayed along with active threads having an empty plan name. This APAR will change the behavior introduced by UK31434 such as the threads in Identify/Signon status will not be displayed in ZALLT / TEP anymore. Along with filtering threads in Identify/Signon also threads with a CONNID equal to "DISCONN" will not be shown in ZALLT/TEP anymore. This change will improve the usability and performance of both Classic and TEP interfaces. The solution for PK60439 is included in this fix. COMMENTS: Problem solved with PK59938
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component * * - OMEGAMON Server * * - Tivoli Enterprise Monitoring Agent * * - Classic Interface * **************************************************************** * PROBLEM DESCRIPTION: - PK59938: * * Too many threads are showing on * * Classic and TEP User Interfaces. * * - UK31434 (PE flagged) correction: * * Distributed threads are not showing * * on Classic Displays. * * - UK33232 (PE flagged) correction: * * OB0910: Program Check - Recovery * * Successful-OPCN+05D0 is issued when * * option "D" on main classic panel is * * entered to display DDF threads. * **************************************************************** * RECOMMENDATION: Apply this PTF. * **************************************************************** PROBLEM SUMMARY: - PK59938: All threads including threads in inactive reuse status and signon identify status threads were being displayed. - UK31434 (PE flagged) correction: Distributed threads were being filtered out of displays. - UK33232 (PE flagged) correction: Router module O2OPCN terminates abnormally on return from called distributed thread routines. PROBLEM CONCLUSION: - PK59938: Remove threads in inactive reuse status and signon identify status from the displays. - UK31434 (PE flagged) correction: Fix filtering process to include distributed threads. - UK33232 (PE flagged) correction: Changed O2OPCN code to bypass the MODEPROB macro call. KEYWORDS: - INACTIVE REUSE ZALLT SIGNON IDENTIFY - DISTRIBUTED THREADS MISSING DFST THDD DSYS - OB0910 KO2OPCNB PROGRAM CHECK OFFSET +05D0 DISPLAY DDF THREADS
Problem conclusion
- PK59938: Remove threads in inactive reuse status and signon identify status from the displays. - UK31434 (PE flagged) correction: Fix filtering process to include distributed threads. - UK33232 (PE flagged) correction: Changed O2OPCN code to bypass the MODEPROB macro call. KEYWORDS: - INACTIVE REUSE ZALLT SIGNON IDENTIFY - DISTRIBUTED THREADS MISSING DFST THDD DSYS - OB0910 KO2OPCNB PROGRAM CHECK OFFSET +05D0 DISPLAY DDF THREADS
Temporary fix
Comments
APAR Information
APAR number
PK59938
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
410
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2008-01-29
Closed date
2008-02-07
Last modified date
2017-02-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK33464
Modules/Macros
KO2APCBA KO2APCBS KO2APCB2 KO2APCCA KO2APCCS KO2APCC2 KO2APC1A KO2APC1S KO2APC12 KO2APC2A KO2APC2S KO2APC22 KO2APC3A KO2APC3S KO2APC32 KO2APC4A KO2APC4S KO2APC42 KO2APC9A KO2APC9S KO2APC92 KO2CCAFA KO2CCAFS KO2CCAF2 KO2CCPUB KO2CDFCA KO2CDFCS KO2CDFC2 KO2CDSYA KO2CDSYS KO2CDSY2 KO2CIFIA KO2CIFIS KO2CIFI2 KO2CLKDA KO2CLKDS KO2CLKD2 KO2CLKRC KO2CLKRD KO2CLKRE KO2CNADB KO2CNASB KO2CTHIA KO2CTHIS KO2CTHI2 KO2CTHSA KO2CTHSS KO2CTHS2 KO2CTH1A KO2CTH1S KO2CTH12 KO2CTH2A KO2CTH2S KO2CTH22 KO2CT2IA KO2CT2IS KO2CT2I2 KO2CT2SA KO2CT2SS KO2CT2S2 KO2NCSTB KO2NXCPB KO2ODSTB KO2OHILB KO2OLOKB KO2OOPTB KO2OPCNB KO2OSYXB KO2OTHAB KO2OTHBB KO2OTHCB KO2OTHDB KO2OTHEB KO2OTHFB KO2OTHGB KO2OTHHB KO2OTHIB KO2OTHLB KO2OTHXB KO2OTH1B KO2OTH2B KO2OTH3B KO2OTH4B KO2OTH5B KO2OTH6B KO2OTH7B KO2OTH8B KO2OTH9B KO2OUTLB KO2OXCMB KO2OXDVB KO2OXIMB KO2OXSYB KO2OXTHB KO2OXTRB KO2OXTSB KO2OZM2B KO2OZOMB KO2WGETB KO2WXCPB KO2XLKDA KO2XLKDS KO2XLKD2 KO2XLKRC KO2XLKRD KO2XLKRE KO2XTHSA KO2XTHSS KO2XTHS2
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R410 PSY UK33464
UP08/02/09 P F802 Ø
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: