  • Closed as documentation error.

Error description

  • The range of the group is different from the SWIFT Handbook.
    The range of the group RTRN is "0:1" though the qualifier RTRN
    is defined as "R" in the SWIFT Handbook.
    
    In essence our type trees are not correct within the SWIFT pack
    provided by IBM.
    
    .
       Message Type  MT542 and MT543
       Block         E
       Tag           22F
       Qualifier     RTRN
    
    SWIFT SR2007 TypeTree (Pack for swift4.2.1_81)
    

Local fix

  • WTXCQ - WTX00003167
    RN / RN
    The range for RTRN in Sequence E, tag 22F, has been changed from
    (0:1) to (s) and can now repeat for MT542 and MT543.
    

Problem summary

  • Of the two issues reported, one is a defect and one is not.
    
    The first issue, the different order of qualifiers within a
    group, is not a defect.  These qualifiers are in an unordered
    group.  An unordered group has one or more components that can
    appear in the data stream in any order.  They allow many SWIFT
    message types to be defined in a more natural way.  When a group
    is defined as Unordered, any component can appear in the data
    stream.
    
    The second issue, the range of the RTRN qualifier being
    different from the SWIFT Handbook, is a valid defect.  The range
    for RTRN in Sequence E, tag 22F, has been changed from (0:1) to
    (s) and can now repeat for MT542 and MT543.
    

Problem conclusion

  • Of the two issues reported, one is a defect and one is not.
    
    The first issue, the different order of qualifiers within a
    group, is not a defect.  These qualifiers are in an unordered
    group.  An unordered group has one or more components that can
    appear in the data stream in any order.  They allow many SWIFT
    message types to be defined in a more natural way.  When a group
    is defined as Unordered, any component can appear in the data
    stream.
    
    The second issue, the range of the RTRN qualifier being
    different from the SWIFT Handbook, is a valid defect.  The range
    for RTRN in Sequence E, tag 22F, has been changed from (0:1) to
    (s) and can now repeat for MT542 and MT543.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK56228

  • Reported component name

    WSTX PK SWIFTNT

  • Reported component ID

    5724M6001

  • Reported release

    810

  • Status

    CLOSED DOC

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2007-11-08

  • Closed date

    2008-04-04

  • Last modified date

    2008-04-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSD8","label":"IBM Transformation Extender"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.1","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
04 April 2008