Error description
Time-out occurs in writer of pipe FABYPIPE.#03 after FABY107A is issued because exclusive use conflict occurs in getting DFSURWF3 record.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IMS High Performance Prefix * * Resolution for z/OS Version 3 Release 1 * * (FMID=H1IP310). * **************************************************************** * PROBLEM DESCRIPTION: FABY107A is issued in prefix update * * process, because HPPR does not release * * exclusive control of CI/BLOCK * * explicitly. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * * Apply the maintenance for this APAR. * **************************************************************** FABY107A is issued in prefix update process, because HPPR does not release exclusive control of CI/BLOCK explicitly. When the update of the CI/BLOCK is unnecessary, HPPR removes the information of the CI/BLOCK from the buffer control block without releasing exclusive control of the CI/BLOCK. So, if the CI/BLOCK is read again, exclusive use conflict occurs and HPPR issues the message FABY107A. When concurrent prefix update is processed, the exclusive use conflict may cause timeout in writer of pipe FABYPIPE.#03 and HPPR issues the message FABY2004E.
Problem conclusion
HPPR has been modified to release exclusive control of CI/BLOCK explicitly when the update of the CI/BLOCK is unnecessary and HPPR removes the information of the CI/BLOCK from the buffer control block.
Temporary fix
Comments
APAR Information
APAR number
PK55352
Reported component name
IMSPREFIXRESOLU
Reported component ID
5655I1500
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2007-10-24
Closed date
2007-11-09
Last modified date
2007-12-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK31063
Modules/Macros
FABYUBH0 FABYUOS0 FABYUVS0 FABYWMT
| SC18923000 |
Fix information
Fixed component name
IMSPREFIXRESOLU
Fixed component ID
5655I1500
Applicable component levels
R310 PSY UK31063
UP07/11/10 P F711