APAR status
Closed as new function.
Error description
Current Incremental Image Copy capabilities in DRF generates a new ICR to the current time. Customer wants the to be able to perform a timestamp Incremental IC to generate a BATCH image copy at a previous time.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: IMS Database Recovery Facility Version 3 * * Release 1 users who use the Incremental * * Image Copy function. * **************************************************************** * PROBLEM DESCRIPTION: The current implementation of the DRF * * Incremental Image Copy (ICR) function * * does not allow an image copy to be * * generated to a timestamp chosen by the * * user. * **************************************************************** * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF * **************************************************************** Users require an ability to generate a BATCH Incremental Image Copy to a timestamp. Currently in order for an Incremental Image Copy to be recognized as a BATCH, an IMS CMDDBR needs to be issued or OLDS must be archived prior to generating the image copy. If generating an Incremental Image Copy to a timestamp is allowed, the image copy will be able to run to a time identified by the user that is after the OLDS have been archived.
Problem conclusion
Temporary fix
Comments
FRXBDMG0 and FRXMTC are changed to replace the text in MSGFRD6124A from "SPECIFIC VALUE OF RCVTIME IS NOT ALLOWED FOR AN INCREMENTAL IMAGE COPY" to say "NOT SUPPORTED WITH INCREMENTAL IC TYPE". FRXEPSS0 is changed to allow the RCVTIME parameter for a timestamp to be supplied for OUTPUT(ICR) processing. RCVTIME is still not allowed for OUTPUT(ICRCA) processing and will cause DRF to fail with MSGFRD6124A INVALID DATA ENCOUNTERED. KEYWORD: RCVTIME RSN=NOT SUPPORTED WITH INCREMENTAL IC TYPE Specifying OUTPUT(ICR) with PITR will also fail with MSGFRD6124A INVALID DATA ENCOUNTERED. KEYWORD: PITR RSN=NOT SUPPORTED WITH INCREMENTAL IC TYPE FRXIAUX is changed to pass the timestamp from the RCVTIME paramenter to HPIC if one is supplied for the Incremental Image Copy process. FRXIOCN0, FRXIOSM0, FRXIVCN0, and FRXIVSM0 are recompiled to pick up changes from FRXIAUX. The following DOC changes are also made: --------------------------------------------------------------- IMS Database Recovery Facility for z/OS User's Guide and Reference Version 3 Release 1 (SC18-9407-01) Chapter 7. Messages and Codes of IMS Database Recovery Facility FRD6124A INVALID DATA ENCOUNTERED. KEYWORD: keyword RSN=rsn Changed the following reason description: SPECIFIC VALUE OF RCVTIME IS NOT ALLOWED FOR AN INCREMENTAL IMAGE COPY ... To say: NOT SUPPORTED WITH INCREMENTAL IC TYPE The OUTPUT(ICR) process will terminate if specified with PITR on the RECOVER START input control statement. This combination is not supported. An Incremental Image Copy cannot be taken to any point-in-time. An Incremental Image Copy can, however, be taken to a specified timestamp where a database was previously brought offline, archive of OLDS occurred, or to a batch window. The OUTPUT(ICRCA) process will terminate if specified with RCVTIME. This combination is not supported. The ICRCA process determines the latest available timestamp that can be used to ensure that a batch image copy is generated.
APAR Information
APAR number
PK41872
Reported component name
IMS DB RECOVERY
Reported component ID
5655I4400
Reported release
310
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2007-03-22
Closed date
2007-05-25
Last modified date
2008-04-30
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK25538
Modules/Macros
FRXBDMG0 FRXEPSS0 FRXIAUX FRXIOCN0 FRXIOSM0 FRXIVCN0 FRXIVSM0 FRXMTC
| SC18940701 |
Fix information
Fixed component name
IMS DB RECOVERY
Fixed component ID
5655I4400
Applicable component levels
R310 PSY UK25538
UP07/05/30 P F705
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX88Z","label":"IMS Database Recovery Facility"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0"}]
Document Information
Modified date: