Error description
When the size of the original ADS VSAM allocation is equal to the size of the expanded ADS VSAM allocation, that is, the two ADS's have the same DMACFBAD, if there is no SDEP defined in the DBD definition, OAE abends with U1026 SC57 because the CI RBA specified to read is outside the valid range. This is a retro-fit of HPFPU V3R1 FPO APAR PK37534 .
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All Online Area Extender users of High * * Performance Fast Path Utilities Fast Path * * Online tools Version 2 Release 2 * * (FMID: H31A220). * **************************************************************** * PROBLEM DESCRIPTION: Backward Fit APAR of HPFPU V3R1 * * PK37534. * * Online Area Extender Shadow expansion * * abends with U1026 SC57 when the area * * was expanded from 'ROOT=(08701,00888)' * * to 'ROOT=(08711,00898)'. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** Backward Fit APAR of HPFPU V3R1 PK37534. Online Area Extender Shadow expansion failed with ABEND U1026 SC57 when the area was expanded from 'ROOT=(08701,00888)' to 'ROOT=(08711,00898)', while the allocation size of original ADS and the size of expanded ADS were same, and there was no SDEP definition in the DBD definition. The problem was caused by the incorrect calculation of REORG UOW size.
Problem conclusion
The macro FPXBFRO0 has been modified to correct the calculation of REORG UOW size. The module FPXBFRO7, FPXBFRO8 and FPXBFRO9 have been reassembled to include the modified FPXBFRO0. The JCLIN H31A220J has been modified to add 'LINK073' step to change the EXEC parameter of some modules from Non-REUS to REUS. The modules below have been reassembled to reflect the modification of JCLIN H31A220J. FPXDCBP0,FPXDCCS0,FPXDCEX0,FPXDCFP0,FPXDCPR0,FPXDCSE0,FPXDCTL0, FPXDDRV8,FPXDDRV9,FPXDEC00,FPXDEDC0,FPXDEIO0,FPXDEMC0,FPXDEMD0, FPXDUCN0,FPXUCDT0,FPXUCSB0,FPXULOD0,FPXUMLD0,FPXUSIT0,FPXUXIN0. 220Y FPXBFRO0 FPXBFRO7 FPXBFRO8 FPXBFRO9 FPXDCBP0 FPXDCCS0 FPXDCEX0 FPXDCFP0 FPXDCPR0 FPXDCSE0 FPXDCTL0 FPXDDRV8 FPXDDRV9 FPXDEC00 FPXDEDC0 FPXDEIO0 FPXDEMC0 FPXDEMD0 FPXDUCN0 FPXUCDT0 FPXUCSB0 FPXULOD0 FPXUMLD0 FPXUSIT0 FPXUXIN0 H31A220J
Temporary fix
Comments
APAR Information
APAR number
PK39163
Reported component name
IMS HP FP UTILI
Reported component ID
5655K9400
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2007-02-09
Closed date
2007-02-22
Last modified date
2007-03-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK22366
Modules/Macros
FPXBFRO0 FPXBFRO7 FPXBFRO8 FPXBFRO9 FPXDCBP0 FPXDCCS0 FPXDCEX0 FPXDCFP0 FPXDCPR0 FPXDCSE0 FPXDCTL0 FPXDDRV8 FPXDDRV9 FPXDEC00 FPXDEDC0 FPXDEIO0 FPXDEMC0 FPXDEMD0 FPXDUCN0 FPXUCDT0 FPXUCSB0 FPXULOD0 FPXUMLD0 FPXUSIT0 FPXUXIN0 H31A220J
Fix information
Fixed component name
IMS HP FP UTILI
Fixed component ID
5655K9400
Applicable component levels
R220 PSY UK22366
UP07/02/24 P F702