IBM Support

PK38289: OBJECT ANALYSIS ACTIVE, STOPPING SERVER WITH BOTH DB2 V7 AND DB2 V8, USER EXPERIENCES AN ABEND AND DB2 V8 SHUTS DOWN.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • With Object Analysis active,  user does a stop of the OMPE
    servers and the db2 v810 subsystem takes an abend.
    .
    communication between DB2 and Media manager is being modified
    and thus causes the abend0c4.
    A 31-bit termination routine address is passed from db2 to
    Media Manager during dataset open.  The address is being
    modified by OMPE.
    
    IBM CORPORATION *** ....O2EIX1
     V31051012/18/06 13:42. PK36362
    the MMIB termination exit address is 9EEADEB0.
    which points to our module o2eix1.
    Module addresses do not have the AMODE bit turned on.
    .
    KO2E3078S OBJECT ANALYSIS followed by ABENDD23
    SD23
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   OMEGAMON Server                          *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1. Object Analysis caused DB2 V8        *
    *                      subsystem to abnormally terminate       *
    *                      with ABEND0C4.                          *
    *                      2. Object Analysis abnormally           *
    *                      terminates with ABENDD23 during DB2     *
    *                      module version verification checking.   *
    ****************************************************************
    * RECOMMENDATION: APPLY THIS PTF.                              *
    ****************************************************************
    1. The termination address in the DB2 MMIB control structure is
    not restored properly by Object Analysis causing DB2 V8
    subsystems to abnormally terminate.
    2. WTO message is issued with invalid message buffer address
    causing Object Analysis to terminate.
    

Problem conclusion

  • 1. Object Analysis has been changed to correctly restore the
    termination address in the DB2 MMIB control structure.
    2. Object Analysis has been changed to issue the WTO message
    with a valid buffer address.
    
    KEYWORDS : ABEND0C4 ABENDD23 KO2EOJSA OBJECT ANALYSIS DSNYECTE
               ICYEXIT
    

Temporary fix

  • *********
    * HIPER *
    *********
    
    DISABLE OBJECT ANALYSIS COMPONENT
    

Comments

APAR Information

  • APAR number

    PK38289

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    410

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2007-01-29

  • Closed date

    2007-02-06

  • Last modified date

    2007-04-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK21897 PK42499

Modules/Macros

  •    KO2EOJSS KO2EOJS2
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R310 PSY UK21897

       UP07/02/08 P F702 Ž

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.