Error description

  • The new DFHSYDMP program  in, CICS TS 5.4,  sets up a system
    dump code for message DFHSO1000.  This, in turn, causes a
    system dump to be taken even in the case where a CONNECT_SOCK
    fails due to timeout.  This can cause multiple unnecessary
    dumps.  This APAR is being taken to explore changing DFHSOS12,
    to only issue an exception trace entry for an AioRc of 1127
    (x'467') meaning ETIMEDOUT and to not call DFHMEME to issue
    message DFHSO1000.
    
    SO 0E03 SOUS  *EXC* - ASYNCIO_REQUESTED_FUNCTION_ERROR
    RETURN_VALUE(-1) RETURN_CODE(1127) REASON_CODE(769E0291)
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICS users.                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: An SO1000 system dump is taken for      *
    *                      message DFHSO1000 when an IPCONN        *
    *                      has a HOST IP address that is valid     *
    *                      but not in use.                         *
    ****************************************************************
    The PLTPI SIT parameter had a value other than NO so
    CICS initialization invoked PLT programs, including the
    user-replaceable module (URM) DFHSYDMP. DFHSYDMP used EXEC CICS
    SET SYSDUMPCODE to add an entry for dump code SO1000 to the
    system dump table.
    An attempt was then made to ACQUIRE an IPCONN with a HOST IP
    address that was valid but not in use. Message DFHSO1000 was
    output, with sufficient information to diagnose the issue with
    the IPCONN. A system dump was also taken which was not needed
    to resolve the issue.
    

Problem conclusion

  • The EXEC CICS SET SYSDUMPCODE request to add dump code SO1000 to
    the system dump table is commented out in DFHSYDMP. The request
    could be reinstated by editing the URM if a system dump is
    needed to resolve a TCP/IP communications failure reported
    by DFHSO1000.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI91601

  • Reported component name

    CICS TS Z/OS V5

  • Reported component ID

    5655Y0400

  • Reported release

    100

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / CST / Xsystem

  • Submitted date

    2017-12-15

  • Closed date

    2018-01-31

  • Last modified date

    2018-02-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI53566

Modules/Macros

  • DFHSYDMP
    

Fix information

  • Fixed component name

    CICS TS Z/OS V5

  • Fixed component ID

    5655Y0400

Applicable component levels

  • R100 PSY UI53566

       UP18/02/01 P F801

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.4","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.4","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
06 February 2018