A fix is available
APAR status
Closed as program error.
Error description
When an ELSE block is empty save for a CONTINUE or NEXT STATEMENT statement, the SNAPSHOT FALSEIF hint appears after the END-IF label, causing the code coverage tool to always mark both the THEN and the ELSE branches of the IF taken.
Local fix
Where possible, remove the empty block
Problem summary
**************************************************************** * USERS AFFECTED: Users debugging modules compiled with * * Enterprise COBOL V5.2 containing an ELSE * * clause with only a CONTINUE inside it. * **************************************************************** * PROBLEM DESCRIPTION: Debugger may show that both the true * * and false path are taken on an IF * * clause. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** The ELSE clause containing only a CONTINUE was seen as empty and seen as the code following the IF condition.
Problem conclusion
Compiler was updated to properly keep track of an empty ELSE clause.
Temporary fix
Comments
APAR Information
APAR number
PI89861
Reported component name
ENT COBOL FOR Z
Reported component ID
5655W3200
Reported release
520
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-11-06
Closed date
2017-11-23
Last modified date
2017-12-07
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
PI90581 PI91249
Modules/Macros
IGY8RWTU IGYCBE IGYCCBE IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOB2 IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYECWI IGYMSGE IGYMSGK IGYMSGT
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655W3200
Applicable component levels
R520 PSY UI52092
UP17/11/30 P F711
R521 PSY UI52093
UP17/12/01 P F711
R522 PSY UI52094
UP17/12/01 P F711
R52H PSY UI52095
UP17/11/30 P F711
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"LOB17","label":"Mainframe TPS"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"","label":""}}]