A fix is available
APAR status
Closed as program error.
Error description
customer experienced the following abend during OMPE collector startup KO2R0900E ERROR DETECTED BY KO2PCSV S0C1 U0000 RC=00000001 PSW= 070C2000 9B3A714C AT KO2PLIO +003A4C D2511 (SNAPDUMP) KO2O1318I NEAR-TERM HISTORY DATA COLLECTOR - NEW OPTIONS IN EFFECT FOR CURRENT INTERVAL (NEWINOPT) KO2O1308I NEAR-TERM HISTORY DATA COLLECTOR ACTIVELY MONITORING DB2 DB1Q (H2WLMGRE) KO2O1360E NEAR-TERM HISTORY DATA COLLECTOR - DATA CAPTURE FAILED WITH RC=0C, RSC=0228, ARSC=0004 DB2=DB2N (CHKRETCD) IEA794I SVC DUMP HAS CAPTURED: 866 866 DUMPID=004 REQUESTED BY JOB (CANSO2 ) 866 DUMP TITLE=OMEGAMON II FOR DB2: COMPID=5655OPE00, JOB=CANSO2 , 866 LMOD=KO2PCSVF#L, CSECT=KO2PLIO , OFFSET=003A4C KO2R0102I DRIVER TERMINATED (CPTERM ) KO2O1310I NEAR-TERM HISTORY DATA COLLECTOR SERVER KO2SSRVB DB2N HAS TERMINATED (SERVINIE)
Local fix
apply PTF when available
Problem summary
**************************************************************** * USERS AFFECTED: USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component * * - Classic Interface * * - CUA Interface * * - NTH - Near Term History * **************************************************************** * PROBLEM DESCRIPTION: ABEND 0C4 or 0C1 in program KO2PCSVF * * CSECT KO2PLIO after several hundreds * * of Start/Stop cycles of Near Term * * History collector. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** Dataspaces used by Near Term History were not removed during termination of NTH collector.
Problem conclusion
Logic was changed to remove dataspaces correctly during termination of NTH collector. Search Keywords: ABEND 0C4 0C1 KO2PCSVF KO2PLIO
Temporary fix
Comments
APAR Information
APAR number
PI86484
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
520
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-08-28
Closed date
2017-09-15
Last modified date
2017-10-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI50372
Modules/Macros
KO2PDRVF KO2PLIOF KO2PUSIF
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R520 PSY UI50372
UP17/09/21 P F709
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]