Fixes are available
APAR status
Closed as program error.
Error description
RIT test fails to connect to IMS and gives HWS0008E EOFException. STEPS TO REPRODUCE : You record an IMS Connect interaction that uses message exit HWSSMPL0 (*SAMPLE*). You then create and run a test based on the recorded messages. EXPECTED RESULTS : You would expect the test to run successfully. ACTUAL RESULTS : You see an error of type HWS0008E: Failed to send or receive messages to and from IMS Connect hostName [xxx.xxx.xxx.xxx], portNumber [yyyy]. Original error: [EOFException]. This is due to the wrong message exit being sent to IMS Connect. WORKAROUND : None
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * users connecting to IMS systems * **************************************************************** * PROBLEM DESCRIPTION: * * RIT would fail to connect to IMS * **************************************************************** * RECOMMENDATION: * * Upgrade to RIT version 9.1.1.1 * ****************************************************************
Problem conclusion
Version 9.1.1.1 of RIT includes a fix for this issue.
Temporary fix
Comments
APAR Information
APAR number
PI82143
Reported component name
RATL INTEGRA TE
Reported component ID
5725G79IT
Reported release
901
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-05-25
Closed date
2017-12-19
Last modified date
2017-12-19
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL INTEGRA TE
Fixed component ID
5725G79IT
Applicable component levels
R800 PSN
UP
R801 PSN
UP
R850 PSN
UP
R851 PSN
UP
R860 PSN
UP
R870 PSN
UP
R871 PSN
UP
R900 PSN
UP
R901 PSN
UP
R910 PSN
UP
R911 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSBLQQ","label":"Rational Test Workbench"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"901","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
18 October 2021