IBM Support

PI79728: MESSAGE HAAB574W AND TAPE STACKING OFF FOR PBG TABLESPACE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When building a Reorg for a PBG tablespace with a LOB column and
    MAXPARTITIONS set to 1, the following message is issued by
    the build:
    HAAB574W Tape Stacking has been turned off because this
    Tablespace with a LOB column will default AUX to Yes.
    This message should not be issued and tape stacking should not
    be turned off in this case because the AUX parameter only
    defaults to YES for a PBG tablespace when MAXPARTITIONS is
    greater than 1.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IBM DB2 Automation Tool z/OS.       *
    ****************************************************************
    * PROBLEM DESCRIPTION: When building a Reorg for a PBG         *
    *                      tablespace with a LOB column and        *
    *                      MAXPARTITIONS set to 1, the following   *
    *                      message is issued by the build:         *
    *                      HAAB574W Tape Stacking has been turned  *
    *                       off because this Tablespace with a     *
    *                       LOB column will default AUX to Yes.    *
    *                      This message should not be issued and   *
    *                      tape stacking should not be turned off  *
    *                      in this case because the AUX parameter  *
    *                      only defaults to YES for a PBG          *
    *                      tablespace when MAXPARTITIONS is        *
    *                      greater than 1.                         *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI79728

  • Reported component name

    DB2 AUTOMATION

  • Reported component ID

    5697G6300

  • Reported release

    420

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-04-10

  • Closed date

    2017-05-15

  • Last modified date

    2017-06-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI47254 UI47255

Modules/Macros

  •    HAA#UTED
    

Fix information

  • Fixed component name

    DB2 AUTOMATION

  • Fixed component ID

    5697G6300

Applicable component levels

  • R420 PSY UI47254

       UP17/05/25 P F705

  • R430 PSY UI47255

       UP17/05/25 P F705

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUWB","label":"IBM Db2 Automation Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.2.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
12 February 2021