IBM Support

80103352 during OSA activation

Troubleshooting


Problem

EZZ4308I ERROR: CODE=80103352 DURING ACTIVATION OF DEVICE xxxxx. DIAGNOSTIC CODE: 02 The 80103352 DLC code refers to a duplicate channel identification. The channel identification subfield was specified more than one time.

Cause

The same OSA subchannel addresses for the failing OSA device were specified on other VTAM definitions.

Resolving The Problem

Remove the duplicate subchannel definitions from other TRLE or XCA VTAM definitions.

Refer to z/OS V2R3 CS: SNA Resource Definition Reference for details.

[{"Product":{"code":"SSSN3L","label":"z\/OS Communications Server"},"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Component":"All","Platform":[{"code":"PF035","label":"z\/OS"}],"Version":"2.1;2.2;2.3","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]