A fix is available
APAR status
Closed as new function.
Error description
Two enhancements are being made as follows: 1. The IMS Connect Extensions Resume Tpipe report may not report sessions due to missing Resume Tpipe commands in the IMS Connect Extensions journal. This is especially true for Resume Tpipe Noauto with no timeout value specified. To correct this issue IMS Connect Extensions APAR PI59534 added an extension to the x'58' event that contains information about the Resume Tpipe command that resulted in the asynchronous output message being returned. The Resume Tpipe report will now create a session entry when a x'58' event is processed that contains the extension and there is not a session entry in the IMS PA report queue. The characteristics of the Resume Tpipe session are filled in from the x'58' extension data. 2. Add new form field: SCOTPIPE - Sync Callout Tpipe name
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS Performance Analyzer V4.4 * **************************************************************** * PROBLEM DESCRIPTION: Improve IMS Connect Extensions Resume * * Tpipe report and add new form field. * **************************************************************** * RECOMMENDATION: * **************************************************************** Two enhancements are being made as follows: 1. The IMS Connect Extensions Resume Tpipe report may not report sessions due to missing Resume Tpipe commands in the IMS Connect Extensions journal. This is especially true for Resume Tpipe Noauto with no timeout value specified. To correct this issue IMS Connect Extensions APAR PI59534 added an extension to the x'58' event that contains information about the Resume Tpipe command that resulted in the asynchronous output message being returned. The Resume Tpipe report now creates a session entry when a x'58' event is processed that contains the extension and there is not a session entry in the IMS PA report queue. The characteristics of the Resume Tpipe session are filled in from the x'58' extension data. 2. Add new form field: - SCOTPIPE - Sync Callout Tpipe name
Problem conclusion
Temporary fix
Comments
Two enhancements are being made as follows: 1. The IMS Connect Extensions Resume Tpipe report may not report sessions due to missing Resume Tpipe commands in the IMS Connect Extensions journal. This is especially true for Resume Tpipe Noauto with no timeout value specified. To correct this issue IMS Connect Extensions APAR PI59534 added an extension to the x'58' event that contains information about the Resume Tpipe command that resulted in the asynchronous output message being returned. The Resume Tpipe report now creates a session entry when a x'58' event is processed that contains the extension and there is not a session entry in the IMS PA report queue. The characteristics of the Resume Tpipe session are filled in from the x'58' extension data. 2. Add new form field: - SCOTPIPE - Sync Callout Tpipe name
APAR Information
APAR number
PI72637
Reported component name
IMS PERF ANALYZ
Reported component ID
5655E1500
Reported release
440
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / Xsystem
Submitted date
2016-11-21
Closed date
2016-11-30
Last modified date
2018-11-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI43026
Modules/Macros
IPI$0243 IPICTPIX IPIFCOMD IPIFOCMD IPIFTCMD IPIIPROC IPILCA01 IPIPXCAX IPIRFMET IPISAPAR IPISINFL IPISXCAR IPITDMGR IPI4DMGR IPI4PROC
| SC19436500 |
Fix information
Fixed component name
IMS PERF ANALYZ
Fixed component ID
5655E1500
Applicable component levels
R440 PSY UI43026
UP16/12/06 P F612
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.4.0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A2","label":"IMS Performance Analyzer"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.4.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: