Error description

  • Fast Path Advanced Tool will support IMS Catalog API. By this
    enhancement, all FPA functions will not need to specify an
    IMSACB DD statement if the IMS management of ACBs function is
    enabled.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of HPFPU Fast Path Advanced Tool   *
    *                 (FPA) and FP Stand-alone Database Sensor in  *
    *                 Fast Path Solution Pack Version 1 Release 3  *
    *                 (FMID: HAHQ130).                             *
    ****************************************************************
    * PROBLEM DESCRIPTION: All FPA functions and FP Stand-alone    *
    *                      Database Sensor support IMS management  *
    *                      of ACBs. By this enhancement, they can  *
    *                      retrieve ACB information from the IMS   *
    *                      directory instead of the ACB library.   *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    
    FPA and FP Stand-alone Database Sensor adds a new keyword
    IMSCATHLQ to the GLOBAL command. This keyword specifies the high
    level qualifier of the bootstrap data set of the IMS directory.
    When this keyword is specified, the tool reads the ACB from the
    IMS directory instead of the ACB library by using IMS Tools
    Catalog Interface.
    
    FPA and FP Stand-alone Database Sensor also adds a new keyword
    IMSCATACB_INPUT to the GLOBAL command. This keyword specifies
    whether to retrieve the currently active ACB definition or the
    pending ACB definition from the IMS directory.
    
    FPA UNLOAD command, CHANGE command, and SIMULATE subcommand add
    a new keyword IMSCATACB_OUTPUT. This keyword specifies whether
    to retrieve the currently active ACB definition or the pending
    ACB definition from the IMS directory. This keyword specifies
    the new ACB definition, which is used when an ACB definition
    change is requested.
    
    If you use the new function, you must:
     - Install the IMS Tools Base for z/OS V1.6 (5655-V93).
     - Apply the APAR PI68811 for the IMS V14 (5635-A05).
     - Enable the IMS catalog and the IMS management of ACBs.
     - Specify the IMS Tools Base library (SGLXLOAD) in the STEPLIB
       DD statement of the FPA JCL.
    
    This is an example to unload an area and changing the DEDB area
    definition when IMS management of ACBs is enabled.
    //HFP      EXEC PGM=HFPMAIN0
    //STEPLIB  DD DISP=SHR,DSN=HPFP.SHFPLMD0
    //         DD DISP=SHR,DSN=IMSVS.SDFSRESL
    //         DD DISP=SHR,DSN=IMSVS.PGMLIB
    //         DD DISP=SHR,DSN=ITB.SGLXLOAD
    //NEWRESLB DD DISP=SHR,DSN=IMSVS.PGMLIB.NEW
    //IMSDALIB DD DISP=SHR,DSN=IMSVS.MDALIB
    //OAREA001 DD DISP=OLD,DSN=HPFP.USRFILE
    //HFPRPTS  DD SYSOUT=*
    //HFPPRINT DD SYSOUT=*
    //HFPSYSIN DD *
    GLOBAL
       DBRC=YES,
       IMSCATHLQ=IMSVS.CATALOG,
       IMSCATACB_INPUT=CURRENT
    UNLOAD
       DBD=DEDBJN22,
       IAREA=(DB22AR0),
       OAREA=(DB22AR0),
       IMSCATACB_OUTPUT=PENDING,
       ACBCHK=YES
    
    In this example:
    - The IMSACB DD statement is not specified. The ACB member is
      read from the IMS directory instead of the ACB library because
      IMSCATHLQ=IMSVS.CATALOG parameter is specified.
    - To use IMS Tools Catalog Interface, the SGLXLOAD library of
      IMS Tools Base is included in the STEPLIB DD concatenation.
    - The ACB member for the current DEDB definition is read from
      the IMS directory data set because IMSCATACB_INPUT=CURRENT is
      specified.
    - The ACB member for new DEDB definition is read from the
      staging data set because IMSCATACB_OUTPUT=PENDING is
      specified.
    - All database records are randomized by the randomizer that is
      loaded from the NEWRESLB DD data set.
    

Problem conclusion

Temporary fix

Comments

  • ========================
    = DOCUMENTATION CHANGE =
    ========================
    1. The IMS Fast Path Solution Pack for z/OS Version 1 Release 3
    IMS High Performance Fast Path Utilities User's Guide
    (SC19-4010-03).
    
    All documentation changes made by this APAR are included in the
    fourth edition of the IMS Fast Path Solution Pack for z/OS
    Version 1 Release 3 IMS High Performance Fast Path Utilities
    User's Guide (SC19-4010-03).
    
    2. IMS Solution Packs Data Sensor User's Guide (SC19-3283-03).
    
    For the documentation changes made by this APAR, see
    http://www-01.ibm.com/support/docview.wss?uid=swg27020942#fpsol-
    pak
    

APAR Information

  • APAR number

    PI70018

  • Reported component name

    IMS FP SOLUTION

  • Reported component ID

    5655W1400

  • Reported release

    130

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / New Function / Xsystem

  • Submitted date

    2016-09-30

  • Closed date

    2017-01-05

  • Last modified date

    2017-02-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI43684

Modules/Macros

  •    HFPCCCT0 HFPCCDS0 HFPCCDT0 HFPCDEF0 HFPCDES0
    HFPCFNI0 HFPCMST0 HFPCSUP0 HFPCXCS0 HFPCXCT0 HFPLCCI0 HFPLCC20
    HFPLDBR0 HFPLINI0 HFPLMST0 HFPLTUN0 HFPPRCU0 HFPSDBW0 HFPSGDMB
    HFPSGDMC HFPSGDMD HFPSGDME HFPWMTC0 HFPWMTS0
    

Publications Referenced
SC19401003SC19328303   

Fix information

  • Fixed component name

    IMS FP SOLUTION

  • Fixed component ID

    5655W1400

Applicable component levels

  • R130 PSY UI43684

       UP17/01/07 P F701

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCV35A","label":"IMS Fast Path Solution Pack"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"130"}]

Document Information

Modified date:
03 October 2020